Field Settings
2.2

Standby Electricity Saving

Outline
RK(X)S25/35G2V1B, RK(X)S25/35G2V1B9 Models Only
This function turns power supply OFF to the outdoor unit and sets the indoor unit into energy-
saving mode, thus reducing the power consumption of the air conditioner.
Detail
Following procedure is required for turning ON the function.
1. Check that the main power supply is turned OFF. Turn OFF if it has not been turned OFF.
2. Remove the stop valve cover.
3. Disconnect the selective connector for standby electricity saving.
4. Turn ON the main power supply.
Caution
Before connecting or disconnecting the selective connector for standby electricity saving, make
sure that the main power supply is turned OFF.
210
1
2
3
Function OFF
The standby electricity saving function is turned OFF
before shipping.
SiENBE05-722_A
1
2
3
Function ON
(R11820)