Introduction; Specifications; Controls; Electrical - Intercomp CS1500 User Manual

Crane scale
Hide thumbs Also See for CS1500:
Table of Contents

Advertisement

Introduction

This manual contains specifications, operation instructions, and calibration instructions
for Intercomp's model CS1500 crane scale.

Specifications

Controls

General:
Display:
Indicators:

Electrical

Batteries:
Battery life:
Resolution:
Filtering:
Auto off:
Sleep mode:
Auto-Zero:

Performance

Accuracy:
±0.1% of applied load or ± display graduation, whichever is greater.

Environmental

Humidity:
Temperature:
Zero, lb/kg, Mode, Set, Print, Tare, On, Off
5 ½ digit LED or 5 digit LCD
lb/kg, Gross/Net, Total/Peak
8 X D-size disposable alkaline dry cells or rechargeable Nickel-
Cadmium cells.
Up to 90 hours with alkaline batteries. Approximately 30 hours on a set
of fully charged Ni-Cad cells. (LED display)
20 bit A/D delivers over 1,000,000 internal counts.
6 Pole, 10 Hertz low pass.
Low battery, or after adjustable time without use or motion.
Display sleep mode after adjustable time without use or motion.
Satisfies all HB-44 requirements; selectable 0.6, 1, or 3 graduations.
10 to 95% Non-Condensing
Storage: -40 C to +75 C. / -40 F to +170 F.
Operating -10 C to +50 C. / +14 F to +122 F.
Page 3 of 35
CS1500, Users
Rev T, June, 2010

Hide quick links: