Page 1
Any other use of the system can cause unsafe operating conditions and result in component rupture, fire, or explosion, which can cause serious bodily injury, including fluid injection. GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 COPYRIGHT 1988, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001...
Page 2
This equipment is for professional use only. Read all instruction manuals, tags, and labels before operating the equipment. Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. Do not alter or modify this equipment.
Page 3
WARNING INJECTION HAZARD Fluid from the dispense valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. Fluid injected into the skin is a serious injury.
Page 4
WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury. Ground the equipment and the object being lubricated. Refer to Grounding on page 5. If there is any static sparking or you feel an electric shock while using this equipment, stop dis- pensing immediately.
Page 5
NOTES: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and drawings. Always use Genuine Graco Parts and Accessories, available from your Graco distributor. Grounding Air and fluid hoses: Use only electrically conductive WARNING hoses.
Page 6
Open Drum, Cover Mounted Pumps 2. Connect the 1/4” swivel adapter (104) to the pump Models 225014, 225016, 225781, 233108, fluid outlet. Connect the 1/4” ID fluid hose (103) to the swivel. Connect a suitable dispensing valve or 241034, 241035, 241039, and 241040 extra hose to the 6-ft hose.
Page 7
Installation Air Line and Accessories Note: Install the air line accessories in the order shown in the Typical Installation on page 6. CAUTION Do not hang air accessories directly on the air inlet. The fittings are not strong enough to support acces- sories and may cause one or more to break.
Page 8
Installation Typical Installation For Mobile Mountings See Descriptions of air accessories on page 6. H Compressor J Hold-down rods K Truck bed L Hose reel 01612 Note: See page 6 for the stationary mounting Drum Mounting With Hold-down Kit installation and page 6 for hose and air accessory Models 222071, 222075, 222085, 222091, 223107, installation.
Page 9
Operation Pressure Relief Procedure WARNING WARNING The maximum working pressure of each pump in your system may not be the same. To reduce the INJECTION HAZARD risk of over-pressurizing any part of your system, To reduce the risk of serious injury, in- be sure you know the maximum working pressure cluding fluid injection or splashing in the rating of each pump and its connected compo-...
Page 10
1/4 npt(mbe); 72” long 155541 ADAPTER, 90 ; 1/4 npt(m) x 1/4 npsm(f) swivel 01616 50:1 Fire-Ball, 120-lb drum size Model 225014, Includes items 1 to 4 Model 241034, Includes items 1 to 4, and 7 Part No. Description Qty. 7 or 8 203869 PUMP, 50:1 Ratio Fire-Ball;...
Page 11
Parts Drawings and Lists 50:1 Fire-Ball, 400-lb drum size Model 225016, Includes items 1 to 4 Model 241035, Includes items 1 to 4, and 7 Part No. Description Qty. 203868 PUMP, 50:1 Ratio Fire-Ball; See 306517 for parts 7 or 8 222072 HOSE AND FITTING KIT;...
Page 12
Parts Drawings and Lists 15:1 Fire-Ball, 400-lb drum size Model 222091, Includes items 1 to 5 Model 241038, Includes items 1 to 6 Part No. Description Qty. 206700 PUMP, 15:1 Ratio Fire-Ball; See 306531 for parts 222072 HOSE AND FITTING KIT; See parts on page 10 207366 COVER;...
Page 13
CE Installation Kits CE Installation Kit 241071 For 15:1 Fire-Ball Installations Part No. Description Qty. 156849 NIPPLE, pipe 113286 VALVE, safety; 150 psi (1 MPa, 10 bar) 169971 FITTING, line 110198 COUPLER, line 222011 CLAMP, grounding 109075 REGULATOR, air, with gauge CE Label (not shown) Attention: To comply with CE directives, the CE identification label must be affixed to the back...
Page 15
Sound Data See the pump instruction manual for technical data including wetted parts, port sizes, maximum air consumption, maximum delivery, and so on. Sound data for the pumps on these units are as follows: 15:1 and 50:1 Fire-Ball Pumps Tested at 100 psi (0.7 MPa, 7 bar) at 40 cycles per minute Sound Pressure Level, measured at 1 meter from unit 77.8 dB(A) Sound Power Level, tested in accordance with ISO 9614–2...
Page 16
Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
Need help?
Do you have a question about the 225014 and is the answer not in the manual?
Questions and answers