Download Print this page

Graco fire-ball 300 Instruction Manual page 5

Grease pumps
Hide thumbs Also See for fire-ball 300:

Advertisement

Note: See page 7 for the mobile mounting installation. See page 5 for hose and air accessory installation.
Typical Installation For Stationary Mountings
Key
A
Fluid dispense line
B
Pump ground wire
C
Air regulator
D
Main air supply line
E
Air filter
F
Pump lubricator
G
Pump runaway valve
H
Follow plate
A
Stationary Mounting Layout
1. Plan the layout for easy operator access to the
pump air controls, sufficient room to change
drums, and a secure platform.
2. For ease in changing drums, install a pump eleva-
tor.
Open Drum, Cover Mounted Pumps
Models 225014, 225016, 225781, 233108, 244635,
and 244636.
1. Remove the original drum cover.
2. Place the drum cover (3) on the drum, and fasten
it with the screws and washers provided. Carefully
guide the pump riser tube through the mounting
gasket.
Installation
B
H
06369B
Installing the Hose Kit See Fig. 2
For pumps using Hose Kit 222072
1. Install the 3/8" swivel adapter (102) in the pump air
inlet or air regulator line coupler (d) whichever is
applicable. Connect the 3/8" ID air hose (101) to
the swivel. Connect the air hose to the air acces-
sories.
2. Connect the 1/4" swivel adapter (104) to the pump
fluid outlet. Connect the 1/4" ID fluid hose (103) to
the swivel. Connect a suitable dispensing valve or
extra hose to the 6-ft hose.
For pumps using Hose Kit 222076
1. Install the 1/2" swivel adapter (102) in the pump air
inlet or air regulator line coupler (d) whichever is
applicable. Connect the 1/2" ID air hose (101) to
the swivel. Connect the air hose to the air acces-
sories.
2. Connect the 3/8" swivel adapter (104) to the pump
fluid outlet. Connect the 3/8" ID fluid hose (103) to
the swivel. Connect a suitable dispensing valve or
extra hose to the 6-ft hose.
C
G
E
F
D
307880
5

Hide quick links:

Advertisement

loading