Viessmann VITODENS 200-W Service Instructions Manual page 72

Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Fault
Const.
Weath.-
code on
comp.
the dis-
play
dd
X
dE
X
E4
X
X
E5
X
X
E8
X
X
E9
X
X
EA
X
X
72
System char-
Cause
acteristics
Control mode
Lead break,
without room
room temper-
influence
ature sensor,
heating circuit
A1
Control mode
Lead break,
without room
room temper-
influence
ature sensor,
heating circuit
with mixer
M2
Burner blocked Fault, supply
voltage 24 V
Burner blocked Fault, flame
amplifier
Burner in a fault
The ionisa-
state
tion current
lies outside
the permissi-
ble range
Burner in a fault
The ionisa-
state
tion current
lies outside
the permissi-
ble range dur-
ing calibra-
tion
Burner in a fault
The ionisa-
state
tion current
lies outside
the permissi-
ble range dur-
ing calibra-
tion
Measures
Check the room
temperature sen-
sor, heating circuit
A1 and the remote
control DIP switch
settings (see
page 101).
Check the room
temperature sen-
sor, heating circuit
with mixer M2 and
the remote control
DIP switch settings
(see page 101).
Replace the control
unit.
Replace the control
unit.
Check the ionisa-
tion electrode and
cable.
Press "E
RESET".
Check the ionisa-
tion electrode and
cable.
Check the flue gas
system for tight-
ness.
Press "E
RESET".
Check the ionisa-
tion electrode and
cable.
Press "E
RESET".