Viessmann VITODENS 200-W Service Instructions Manual page 40

Table of Contents

Advertisement

Codes
Code 2
(cont.)
Coding in the delivered condition
21:0
No maintenance interval
(hours run) selected
23:0
No time interval for
burner service selected
24:0
The service display is
reset
25:0
With outside temperature
sensor for constant tem-
perature control units: No
recognition of outside
temperature sensor or
fault monitoring
28:0
No burner interval igni-
tion
2E:0
Without external exten-
sion
2F:0
Venting program/fill pro-
gram disabled
30:0
Internal fixed speed circu-
lation pump (automatic
adjustment, do not mod-
ify)
32:0
Influence of the signal
"External blocking" on cir-
culation pumps: All
pumps in control function
Note
Generally, the burner will be blocked when signal "External blocking" is enabled.
40
Possible change
21:1
The number of hours run
to
before the burner should
21:100
be serviced is adjustable
from 100 to 10 000 h
one step ≙ 100 h
23:1
Interval adjustable from 1
to
to 24 months
23:24
24:1
"Service" display (the
value is automatically set
and must be manually
reset after a service has
been carried out)
25:1
Outside temperature sen-
sor and fault monitoring
recognised
28:1
Time interval adjustable
to
from 1 to 24 h. The burner
28:24
is force-started once every
30 s (only when operating
with LPG)
2E:1
With external extension
(automatic setting on con-
nection)
2F:1
Venting program enabled
2F:2
Fill program enabled
32:1
Influence of the signal
to
"External blocking" on cir-
32:15
culation pumps: See the
following table