Viessmann VITODENS 200-W Service Instructions Manual page 45

Table of Contents

Advertisement

Code 2
(cont.)
Coding in the delivered condition
73:0
DHW circulation pump
"ON" in accordance with
the time program (only for
weather-compensated
control units)
General
76:0
Without LON communi-
cation module (only for
weather-compensated
control units)
77 :1
LON subscriber number
(only for weather-com-
pensated control units)
79:1
With LON communication
module: Control unit is
fault manager (only for
weather-compensated
control units)
7b:1
With LON communication
module: The control unit
transmits the time (only
for weather-compensa-
ted control units)
7F:1
Detached house (only for
weather-compensated
control units)
80:1
If a fault occurs for at least
5 s, a fault message is
displayed
Possible change
73:1
during the time program
to
"ON" 1x/h for 5 min
73:6
"ON" up to 6x/h for 5 min
73:7
Permanently "ON"
76:1
With LON communication
module; automatic recog-
nition
77 :2
LON subscriber number,
to
adjustable from 1 to 99:
77 :99
1 - 4 = Boiler
5 = Cascade
10 - 98 = Vitotronic 200-H
99 = Vitocom
Note
Allocate each number only
once.
79:0
Control unit is not fault
manager
7b:0
Does not transmit time
7F:0
Apartment building
Separate adjustment of
holiday program and time
program for DHW heating,
as option
80:0
Immediate fault message
80:2
The fault message is
to
issued after a delay that is
80:199
adjustable from 10 s to
995 s; one step ≙ 5 s
Codes
45