Viessmann VITODENS 200-W Service Instructions Manual page 42

Table of Contents

Advertisement

Codes
Code 2
(cont.)
Value
Internal cir-
address
culation
34: ...
pump
4
Control
funct.
5
Control
funct.
6
Control
funct.
7
Control
funct.
8
OFF
9
OFF
10
OFF
11
OFF
12
OFF
13
OFF
14
OFF
15
OFF
16
ON
17
ON
18
ON
19
ON
20
ON
21
ON
22
ON
23
ON
Coding in the delivered condition
Boiler/burner
38:0
Status burner control unit:
Operational (no fault)
51:0
Internal circulation pump
is always started when
there is a heat demand
42
Heating cir-
Heating cir-
cuit pump
cuit pump
Heating cir-
Heating cir-
cuit without
cuit with
mixer
mixer
OFF
Control funct.
OFF
Control funct.
OFF
OFF
OFF
OFF
Control funct. Control funct.
Control funct. Control funct.
Control funct. OFF
Control funct. OFF
OFF
Control funct.
OFF
Control funct.
OFF
OFF
OFF
OFF
Control funct. Control funct.
Control funct. Control funct.
Control funct. OFF
Control funct. OFF
OFF
Control funct.
OFF
Control funct.
OFF
OFF
OFF
OFF
Possible change
38:≠0
51:1
Circulation pump for
cylinder heating
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Control funct.
OFF
Fault burner control unit
When there is a heat
demand, the internal circu-
lation pump will only be
started when the burner is
operational. System with
heating water buffer cylin-
der.