Viessmann VITODENS 200-W Service Instructions Manual page 70

Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Fault
Const.
Weath.-
code on
comp.
the dis-
play
b8
X
X
bA
X
bC
X
bd
X
bE
X
bF
X
C2
X
X
70
System char-
Cause
acteristics
Burner blocked Lead break,
flue gas tem-
perature sen-
sor
Mixer M2 regu-
Communica-
lates to 20 °C
tion fault,
flow tempera-
extension kit
ture
for heating
circuit with
mixer M2
Control mode
Communica-
without remote
tion fault,
control
Vitotrol
remote con-
trol, heating
circuit A1
Control mode
Communica-
without remote
tion fault,
control
Vitotrol
remote con-
trol, heating
circuit with
mixer M2
Control mode
Vitotrol
remote con-
trol incor-
rectly pro-
grammed
Control mode
Incorrect
LON commu-
nication mod-
ule
Control mode
Communica-
tion fault,
solar control
unit
Measures
Check the flue gas
temperature sen-
sor (see
page 82).
Check extension
kit connections and
code. Start the
extension kit.
Check connec-
tions, cable, coding
address "A0" and
remote control DIP
switches (see
page 101)
Check connec-
tions, cable, coding
address "A0" and
remote control DIP
switches (see
page 101)
Check remote con-
trol DIP switch set-
tings (see
page 101).
Replace the LON
communication
module.
Check connections
and coding
address "54".