Viessmann VITODENS 200-W Service Instructions Manual page 43

Table of Contents

Advertisement

Code 2
(cont.)
Coding in the delivered condition
52:0
Without flow temperature
sensor for low loss
header
Function connection sK
53:1
of the internal extension:
DHW circulation pump
54:0
Without solar control unit 54:1
DHW
56:0
Set DHW temperature
adjustable from 10 to
60 °C
58:0
Without auxiliary function
for DHW heating
59:0
Cylinder heating:
Start point -2.5 K
Stop point +2.5 K
5b:0
DHW cylinder directly
connected to the boiler
Possible change
52:1
With flow temperature sen-
sor for low loss header
(automatic adjustment on
connection)
Function connection sK:
53:0
Central fault
53:2
Function connection sK:
External heating circuit
pump (heating circuit A1)
53:3
Function connection sK:
External circulation pump
for cylinder heating
With Vitosolic 100 (auto-
matic adjustment on con-
nection)
54:2
With Vitosolic 200 (auto-
matic adjustment on con-
nection)
56:1
Set DHW temperature
adjustable from 10 to
above 60 °C
Note
Maximum value subject to
boiler coding card.
Observe the max. permis-
sible DHW temperature.
58:10
Entry of a second set DHW
to
temperature, adjustable
58:60
from 10 to 60 °C (observe
coding addresses "56" and
"63")
59:1
Start point adjustable from
to
1 to 10 K below set value
59:10
5b:1
DHW cylinder connected
downstream of the low loss
header
Codes
43