Vega VEGAVIB 63 Operating Instructions Manual page 28

Contactless electronic switch
Hide thumbs Also See for VEGAVIB 63:
Table of Contents

Advertisement

9 Supplement
Density
Standard
-
adjustable
-
Granular size
Electromechanical data
Cable entry/plug (dependent on the version)
Single chamber housing
-
Spring-loaded terminals
Adjustment elements
Mode switch
Min.
-
Max.
-
Voltage supply
Operating voltage
Domestic current requirement
Load current
Min.
-
Max.
-
Electrical protective measures
Protection rating
Overvoltage category
Protection class
Approvals
Instruments with approvals can have different technical data depending on the version.
That's why the associated approval documents have to be noted with these instruments. They are
part of the delivery or can be downloaded under www.vega.com via "VEGA Tools" and "serial
number search" as well as via "Downloads" and "Approvals".
28
> 0.05 g/cm³ (0.002 lbs/in³)
> 0.02 g/cm³ (0.0007 lbs/in³)
no limitation
l
or:
l
or:
l
for wire cross-section up to 1.5 mm² (AWG 16)
Min. detection or dry run protection
Max. detection or overflow protection
20 ... 253 V AC, 50/60 Hz, 20 ... 253 V DC
approximately 3 mA (via load circuit)
10 mA
400 mA (at I > 300 mA the ambient temperature can
be max. 60 °C/140 °F) max. 4 A up to 40 ms
IP 66/IP 67
III
I
max. 20 mm (0.8 in) with product density < 0.05 g/cm³ (0.002 lbs/in³).
1)
1)
1 x cable entry M20 x 1.5 (cable: ø 5 ... 9 mm),
1 x blind stopper M20 x 1.5; attached 1 x cable
entry M20 x 1.5
1 x cable entry ½ NPT, 1 x blind stopper ½ NPT,
1 x cable entry ½ NPT
1 x plug M12 x 1; 1 x blind stopper M20 x 1.5
VEGAVIB 63 • - contactless electronic switch