  • Page 1: Operating Instructions

    Operating Instructions VEGAVIB 63 - contactless electronic switch Document ID: 29278 Vibration...
  • Page 2: Table Of Contents

    Supplement Technical data ......26 VEGAVIB 63 • - contactless electronic switch...
  • Page 3: Vegavib 63 • - Contactless Electronic Switch

    You can find them listed in chapter "Product description". Instructions manuals for accessories and replacement parts Tip: To ensure reliable setup and operation of your VEGAVIB 63, we offer accessories and replacement parts. The corresponding documenta- tions are: 31086 - External housing - VEGAVIB...
  • Page 4: About This Document

    This symbol indicates special instructions for Ex applications. List The dot set in front indicates a list with no implied sequence. à Action This arrow indicates a single action. Sequence Numbers set in front indicate successive steps in a procedure. VEGAVIB 63 • - contactless electronic switch...
  • Page 5: For Your Safety

    During work on and with the device the required personal protective equipment must always be worn. 2.2 Appropriate use The VEGAVIB 63 is a sensor for level detection. You can find detailed information on the application range in chapter "Product description".
  • Page 6: Safety Label On The Instrument

    You can find the CE conformity declaration in the download area of "www.vega.com". 2.7 SIL conformity VEGAVIB 63 meets the requirements of functional safety according to IEC 61508. Further information is available in the Safety Manual "VEGAVIB series 60".
  • Page 7: Product Description

    The VEGAVIB 63 consists of the components: Constituent parts Housing cover Housing with electronics Process fitting with vibrating rod Fig. 1: VEGAVIB 63 - with plastic housing Housing cover Housing with electronics Process fitting Type label The type label contains the most important data for identification and...
  • Page 8: Principle Of Operation

    In addition to the type label outside, you can also find the serial number on the inside of the instrument. 3.2 Principle of operation VEGAVIB 63 is a point level sensor with vibrating rod for level Application area detection.
  • Page 9: Operation

    Not exposed to corrosive media Protected against solar radiation Avoiding mechanical shock and vibration Storage and transport Storage and transport temperature see chapter "Supplement - temperature Technical data - Ambient conditions" Relative humidity 20 … 85 % VEGAVIB 63 • - contactless electronic switch...
  • Page 10: Mounting

    You can find the specifications in chapter "Technical data" and on the type label. In general, VEGAVIB 63 can be installed in any position. The Switching point instrument only has to be mounted in such a way that the vibrating element is at the height of the desired switching point.
  • Page 11: Instructions For Installation

    For this reason, do not use an overly long extension tube for VEGAVIB 63, but check if you can mount a short level switch on the side of the vessel in horizontal position.
  • Page 12 4 Mounting Fig. 3: Inflowing medium VEGAVIB 63 can be mounted with a lock fitting for height adjustment. Lock fitting Take note of the pressure information of the lock fitting. Socket The vibrating element should protrude into the vessel to avoid buildup.
  • Page 13 4 Mounting Fig. 4: Filling and emptying centred Fig. 5: Filling in the centre, emptying laterally VEGAVIB 63 Discharge opening Filling opening VEGAVIB 63 • - contactless electronic switch...
  • Page 14 This baffle must be manufactured by you. > 125 mm (> 5") Fig. 6: Baffle for protection against mechanical damage VEGAVIB 63 • - contactless electronic switch...
  • Page 15: Connecting To Power Supply

    Remove approx. 10 cm (4 in) of the cable mantle, strip approx. 1 cm (0.4 in) of insulation from the ends of the individual wires Insert the cable into the sensor through the cable entry VEGAVIB 63 • - contactless electronic switch...
  • Page 16: Wiring Plan, Single Chamber Housing

    10 If necessary, carry out a fresh adjustment 11 Screw the housing cover back on The electrical connection is finished. 5.3 Wiring plan, single chamber housing The following illustrations apply to the non-Ex as well as to the EEx-d version. VEGAVIB 63 • - contactless electronic switch...
  • Page 17 When VEGAVIB 63 is used as part of an overfill protection system according to WHG, also note the regulations of the general type approval.
  • Page 18 5 Connecting to power supply Fig. 9: Wiring plan Shielding VEGAVIB 63 • - contactless electronic switch...
  • Page 19: Set Up

    Note: As a rule, always set the mode with mode switch (2) before starting the setup of VEGAVIB 63. The switching output will change if you set the mode switch (2) afterwards. This could possibly trigger other connected instruments or devices.
  • Page 20: Function Chart

    6 Set up As a default setting, the potentiometer of VEGAVIB 63 is set to the complete right position (> 0.3 g/cm³/0.011 lbs/in³). In very light solids you have to turn the potentiometer to the complete left position (0.02 … 0.1 g/cm³ or 0.0007 … 0.0036 lbs/in³). By doing this, VEGAVIB 63 will be more sensitive and light solids can be detected more reliably.
  • Page 21 6 Set up Level Switching status Control lamp Mode min. Dry run protection Switch open Failure of the sup- ply voltage (min./max. mode) Switch open Malfunction Switch open flashes red VEGAVIB 63 • - contactless electronic switch...
  • Page 22: Maintenance And Fault Rectification

    24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550. The hotline is available to you 7 days a week round-the-clock. Since we offer this service world-wide, the support is only available in the English language.
  • Page 23: Exchanging The Electronics Module

    Pull the connection cables out of the terminals Loosen the two screws with a screw driver (Torx size T10 or slot 4) Fig. 24: Loosening the holding screws Electronics module Screws (2 pcs.) VEGAVIB 63 • - contactless electronic switch...
  • Page 24: Instrument Repair

    If a repair is necessary, please proceed as follows: You can download a return form (23 KB) from our homepage at www. vega.com under: "Downloads - Forms and certificates - Repair form". By doing this you help us carry out the repair quickly and without having to call back for needed information.
  • Page 25: Dismounting

    Correct disposal avoids negative effects on humans and the environ- ment and ensures recycling of useful raw materials. Materials: see chapter "Technical data" If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. VEGAVIB 63 • - contactless electronic switch...
  • Page 26: Supplement

    Sensor length (L) 140 Nm, max. 400 N (103 lbf ft, max. 90 lbf) Max. lateral load Output variable Output Contactless electronic switch Modes (switchable) min./max. Switching delay 0.5 s When immersed When laid bare VEGAVIB 63 • - contactless electronic switch...
  • Page 27 (104°F) 0°C (32°F) -50°C 50°C 100°C 150°C 200°C 250°C (-58°F) (122°F) (212°F) (302°F) (392°F) (482°F) -40°C (-40°F) Fig. 26: Ambient temperature - Process temperature Process temperature Ambient temperature Temperature range with temperature adapter VEGAVIB 63 • - contactless electronic switch...
  • Page 28 Instruments with approvals can have different technical data depending on the version. That's why the associated approval documents have to be noted with these instruments. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools" and "serial number search" as well as via "Downloads" and "Approvals".
  • Page 29: Dimensions

    (3.11") (3.03") M20x1,5 M20x1,5/ M20x1,5/ M20x1,5/ ½ NPT ½ NPT ½ NPT M20x1,5/ ½ NPT Fig. 27: Housing versions Plastic housing Stainless steel housing, electropolished Stainless steel housing - precision casting Aluminium housing VEGAVIB 63 • - contactless electronic switch...
  • Page 30 9 Supplement ø 29mm (1 ") ø16mm ( ") Fig. 28: VEGAVIB 63, threaded version G1 A (DIN ISO 228/1) Sensor length, see chapter "Technical data" VEGAVIB 63 • - contactless electronic switch...
  • Page 31 9 Supplement G1½A ø 29mm (1 ") ø16mm ( ") Fig. 29: VEGAVIB 63, threaded version G1½ A (DIN ISO 228/1) Sensor length, see chapter "Technical data" VEGAVIB 63 • - contactless electronic switch...
  • Page 32 9 Supplement ø 34 mm ") Fig. 30: Temperature adapter VEGAVIB 63 • - contactless electronic switch...
  • Page 33: Information

    Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellectuelle. Pour plus d'informations, on pourra se référer au site http://www.vega. VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad industrial. Para mayor información revise la pagina web http://www.vega.com Линии...
  • Page 34 9 Supplement VEGAVIB 63 • - contactless electronic switch...
  • Page 35 9 Supplement VEGAVIB 63 • - contactless electronic switch...
  • Page 36: Information

    All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information avail- able at the time of printing. © VEGA Grieshaber KG, Schiltach/Germany 2012 29278-EN-120418 Subject to change without prior notice...