4. Physical installation
6. Test the focus by zooming out (minimum image size on screen) and then zooming in again. Verify the image is still sharp. If there
are any deviations to sharpness, repeat steps 2 to 6 until the image is correct.
7. Tighten the three set screws in the following order: left (1b), right (2b) and then top (3b). Use a size 6 hex key to do this.
1b
Image 4-9
1
Image 4-10
2
Image 4-11
3
Image 4-12
34
3b
2b
F
F
F
601–0400–00 F90–W13 18/08/2016