Barco F90–W13 User Manual page 30

Table of Contents

Advertisement

4. Physical installation
Environment
1500 – 3000 M
Maximum air flow
AutoDim function
The F90 AutoDim function is integrated in the projector firmware. The projector continually senses and calculates the ambient
temperature in the installation location and will, when necessary, automatically dim the light output if the projector is operating in the
extreme ends of the recommended ambient environmental conditions, as illustrated in the graph below.
100
95
90
85
80
75
70
34
35
Image 4-1
Mains power requirements
Projector
F90
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that the instrument panel
and cabinet be grounded.
In no event shall this projector be operated without an adequate cabinet ground connection.
The AC supply must be installed by a qualified electrician in conformance to local codes. Hardware, wire sizes and conduit types
must comply with local codes.
AutoDim function will be activated when mains power are 110V or below.
26
Ambient operating
temperature
10 to 35 °C
900 m
/ hour
3
36
37
38
39
Ambient Temperature [
Relative humidity
10 to 80 %
-
40
41
42
43
o
C]
Power requirements
110 — 240 V, 50 — 60 Hz
Storage Conditions
-20 to 60 °C, 10 – 90 %
NA
Rel. Humidity=45%
Rel. Humidity=55%
Rel. Humidity=65%
Rel. Humidity=80%
44
45
601–0400–00 F90–W13 18/08/2016