Table 3-2 (Page 2 of 9). Firmware Error Codes.
Error Code
Description
003
Power on Password must be set for
Unattended mode
004
Battery drained or needs replacement
005
EEPROM locked
008
CMOS corrupted or tampering evident,
CMOS initialized
009
Invalid password entered - system
locked
00A
EEPROM lock problem
00B
EEPROM write problem
00C
EEPROM read problem
017
Cold boot needed for password entry
20EE0xxx
Informational
xxx=003
SMS: Invalid RIPL IP address (requires
3 dots ".")
Chapter 3. Error Code to FRU Index for Model 140 and Model 240
Action/
Possible Failing FRU
Unattended mode requires the setting
of the Power On password before can
be enabled.
1. Replace battery.
2. Replace system board. (See notes
on page 3-1.)
1. Turn off, then turn on system unit.
2. Replace the system board. (See
notes on page 3-1.)
Check your machine for evidence of
tampering.
If no tampering evident:
1. Replace battery, restore NVRAM
data (passwords, startup data)
2. Replace system board. (See notes
on page 3-1.)
The password has been entered
incorrectly 3 times.
Turn off, then turn on the system unit,
then enter the password correctly.
If for priviliged-access password install,
is jumper in correct position?
Consult the system's User's Guide for
jumper location and position.
1. Turn off, turn on system unit.
2. Replace system board. (See notes
on page 3-1.)
1. Turn off, turn on system unit.
2. Replace system board. (See notes
on page 3-1.)
1. Turn off, turn on system unit.
2. Replace system board. (See notes
on page 3-1.)
Turn off, turn on system unit.
Enter valid RIPL IP address.
Example: 000.000.000.000
3-5