Table 4-1 (Page 5 of 11). Firmware Error Codes
Error Code
Function /
Description
21A00001
Test Unit Ready
Failed - hardware
error
21A00002
Test Unit Ready
Failed - sense data
available
21A00003
Send Diagnostic
Failed
21A00004
Send Diagnostic
Failed - DevOfl cmd
21E00xxx
SCSI Tape
21ED0xxx
SCSI Changer
21EE0xxx
Other SCSI device
type
21F00xxx
SCSI CDROM
21F20xxx
SCSI Read/Write
Optical
Network Controller problem
22000001
Internal wrap test
failed.
22001001
Internal wrap test
failed.
22010001
Adapter failed to
complete hardware
initilization.
22011001
Adapter failed to
complete hardware
initilization.
22020001
Adapter failed to
complete hardware
initilization.
Memory Controller problem
25000000
Memory controller
failed
Flash Update problem
Repair Action/Possible Failing FRU
Refer to SCSI device error notes above
1. Replace SCSI device
2. Replace SCSI cable
3. Replace SCSI controller
Refer to SCSI device error notes above
1. Replace Media (Removable media devices)
2. Replace SCSI device
Refer to SCSI device error notes above
1. Replace SCSI device
Refer to SCSI device error notes above
1. Replace SCSI device
Refer to 21A00xxx error codes for a description and
repair action for the specific "xxx" value.
Refer to 21A00xxx error codes for a description and
repair action for the specific "xxx" value.
Refer to 21A00xxx error codes for a description and
repair action for the specific "xxx" value.
Refer to 21A00xxx error codes for a description and
repair action for the specific "xxx" value.
Refer to 21A00xxx error codes for a description and
repair action for the specific "xxx" value.
Replace the card.
Replace the card.
Replace the card.
Replace the card.
Replace the card.
Replace System Planar
Chapter 4. Error Code to FRU Index for the Model 150