Panasonic UF-9000 Service Manual page 164

Hide thumbs Also See for UF-9000:
Table of Contents

Advertisement

No.
Parameter
061 TX/RX/PRT/CPY TX:****** PRT:******
062 Print Counter
063~
Not Used
067
068 NYSE Fax
Forward
(USA and Canada
Only)
069 NYSE Local Print
(USA and Canada
Only)
070 Line Error
071 Total Error
072 Continuous Error 1 = Off (unlimited)
073 Error Detect
074 RTN Receive
075 Coding
076 Batch TX
(USA and Canada
Only)
077 RX JAM Length
Ver. 1.0
Function Parameter Table
Selections
RX:****** CPY:******
1 = Off
2 = On
1 = Off
2 = On
1 = Inc
2 = On (Always)
128 lines
256 lines
512 lines
1024 line
2048 lines
Off
(will not disconnect line)
1 = 5%
2 = 10%
3 = 15%
4 = 20%
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
1 = Lines
2 = Rate
1 = Disconnect
2 = Continue
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR
(MH or MR or MMR)
4 = JBIG
1 = Off
2 = On
1 = Off (unlimited)
2 = 2 m
Displays the transmitted, received, total printed and
copied document count.
Selects whether to print in the Fax Parameter List,
the counter information that is displayed in the
Function Parameter No. 61.
Selects whether the machine will forward the
incoming and outgoing faxes to a specified station.
Note:
Once this parameter is activated, Fax
Forwarding via Fax Parameter 054 is
automatically disabled, an Access Code of
"0000" is automatically assigned and Fax
Parameter 038 has a new setting added called
"NYSE".
Selects the printing condition for the incoming faxes
after FAX Forwarding.
INC. : Prints only if FAX Forwarding fails.
ON
: Always prints.
1. Selects the line disconnect condition during
reception. If the number of line errors exceed this
setting, the unit will disconnect the line.
Press "V" or "/\ " to select the symbol rate.
2. Selects the transmit condition of RTP/PIP or
RTN/PIN.
(Available if No.73 Error Detect is set to "LINES")
(See Note 1)
Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No.73 Error Detect is set to "RATE".)
(See Note 2)
Selects the continuous total error criteria of Off/3/6
or 12 lines in Standard mode. If continuous total
error exceeds this setting, the unit will transmit
RTN/PIN.
(Available if No.73 Error Detect is set to "RATE".)
Selects the error detect condition Lines/Rate.
Selects whether to disconnect the phone line or
continue when "RTN" is received.
Selects the coding scheme.
Selects whether the batch transmission is available.
Selects the maximum length of a received
document that can be printed.
164
UF-9000
DP-180/190
Function
JAN 2004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-180/190

Table of Contents