Fax Information Codes
Phase
Description of Problem
C
CS of modem is not able to turn
ON.
B
Remote unit does not have
compatible Modem.
B, C, D During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
B, C, D CS of modem is not able to turn
ON during training.
B
Polling is rejected from the remote
station.
B
Polling XMT is rejected.
B
No response after transmitting 3rd
CTC or DCN received.
D
No response after transmitting 3rd
EOR or received DCN.
D
No response to the 3rd RR
transmitted or received DCN.
D
T5 timer (60 sec.) elapsed without
MCF.
D
Stopped Transmission after EOR
Transmission.
C
Timer between frames in phase C
has elapsed.
D
Transmitted ERR after receiving
EOR.
D
Transmitted PIN after receiving
EOR.
B
Password or machine code did not
match during remote diagnostic
communication.
B
Remote unit did not have the
remote diagnostic function.
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
B
Sub-address SEP (for Polling)
transmission to a unit that has their
DIS bit 47 (NSF bit 130) OFF.
ADF Door was opened during ADF
transmission.
A
No original was in the ADF. (Built-
in dialer engaged)
FXB PCB is defective.
Line is disconnected.
Transmitter is defective.
SC PCB or FXB PCB are defective.
FXB PCB is defective.
Line is disconnected.
No polling original is set.
No polling original is set.
Incompatible interface.
Line is faulty.
FXB PCB abnormal.
Remote unit is abnormal.
Remote unit is abnormal.
Line is faulty.
FXB PCB abnormal.
Defective remote station.
Line is faulty.
Line is faulty and Operator Call
requested by RX side.
Sub-address transmission to a unit that
has no Sub-address function.
Sub-address transmission to a unit that
has no Sub-address function.
Sub-address transmission to a unit that
has no Sub-address function.
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the ADF.