16.)
The dimension X (dimension between the position of the bypass switch in the respective
stopping point and the start of the plastic strip) must not exceed 10cm; we recommend 6 to 8 cm.
The bypass switch strip is as standard fastened to the entire length of the lower rail part. The
cutouts (dimension X) should be added on location.
17.) Reattach the front paneling to the elevator..
18.) Attach all screw caps, support caps, support screens and track pipe caps.
18a Attach all required hazard and information signs. If applicable, stickers should be covered over
with stickers in the respective country's language!
19.) Multiple test drives under full load and inspection of all safety and operating functions (incl.
function test/engaging of the safety catch).
 Test of the effectiveness of the catch switch by inserting the latch by hand (possibly by
means of a tool (e.g. inch rule)).
 Check of the effectiveness of the safety catch by rotating downwards with ventilated brakes
to the blocking position of the safety catch.
20
Instruct the operator extensively (let him drive himself).
21
Possibly repair occurring paint damages (paint containers are delivered ) , and point out to the
customer that he should not run the system until the paint is dry and the operation is permitted
by the national regulations.
22.) Fill out the assembly report in detail, and send it back to the customer service of the
manufacturer.
Installation manual Konstanz DC
upper
stopping point
17/25
lower
stopping point
Version 8.0