Small Ammounts Of Ice-Cream Mixture; Mixture Treating At The Preseted Temperature - Valmar Sweety Quick 60 Operating And Maintenance Manual

Sweety quick series
Table of Contents

Advertisement

The amount of the mixture shall conform to the technical characteristics of the
machine. During preparation and loading it is needed to comply with the minimum
and maximum mixture amounts in the basin. They are reported in below table:
Appliance type
SWEETY quick/quick-i 60
SWEETY quick/quick-i 130
SWEETY quick/quick-i 180
All performance data is based on standard ice cream mixture production. When producing
mixtures, which include ingredients or additives that increase in volume during heating
and/or cooking, the maximum mixture quantity must be reduced in accordance with the
recipe.

10.6 SMALL AMMOUNTS OF ICE-CREAM MIXTURE

To prepare small amounts of ice mass it is necessary to install a flue damper on
the agitator.
Mixing smaller quantities without flue dampers cause air suction in the mix.
When the mass occupies more than half of the basin volume, the flue damper is
not needed.
For small amounts of ice-cream mixtures it used reduced heating and cooling.
When entering the stage of preparation or refrigeration, the reduction is always off.
If the key of currently selected mode is pressed once again for more than 3
seconds the reduction is switched on or off. If the reduction is activated the led of
the active key is blinking. If the key is pressed again the reduction will be disabled.

10.7 MIXTURE TREATING AT THE PRESETED TEMPERATURE

Ice cream mixture treating process at a preset temperature:
make sure that the control panel is in STOP state;
make sure that the outlet valve is properly set and well closed;
pour ice cream mixture in the cylinder and close the cover lid;
press the AUTOMATIC MIXTURE TREATING key, temperature in the
cylinder is shown on the display, heating phase light indicator lights up;
as soon as mixtures temperature reaches preset temperature 85° C, the
appliance enters COOLING PHASE and the cooling phase light indicator
begins blinking; mixture is cooled down to 4° C;
as soon as mixture reaches temperature 4° C, the appliance enters
MAINTAINING PHASE at a temperature between 4° C and 5° C and the
cooling phase light indicator starts lighting continuously.
min.quantity
max.quantity
(kg)
20
30
60
29
Optimal quantity (kg)
(kg)
60
50
130
110
180
160