GE N60 Instruction Manual page 437

Network stability and synchrophasor measurement system ur series
Hide thumbs Also See for N60:
Table of Contents

Advertisement

APPENDIX A
Table A–1: FLEXANALOG DATA ITEMS (Sheet 11 of 18)
ADDRESS
FLEXANALOG NAME
9223
Synchchk 2 Delta Phs
9224
Synchchk 3 Delta V
9226
Synchchk 3 Delta F
9227
Synchchk 3 Delta Phs
9228
Synchchk 4 Delta V
9230
Synchchk 4 Delta F
9231
Synchchk 4 Delta Phs
9581
PMU 1 Va Mag
9583
PMU 1 Va Angle
9584
PMU 1 Vb Mag
9586
PMU 1 Vb Angle
9587
PMU 1 Vc Mag
9589
PMU 1 Vc Angle
9590
PMU 1 Vx Mag
9592
PMU 1 Vx Angle
9593
PMU 1 V1 Mag
9595
PMU 1 V1 Angle
9596
PMU 1 V2 Mag
9598
PMU 1 V2 Angle
9599
PMU 1 V0 Mag
9601
PMU 1 V0 Angle
9602
PMU 1 Ia Mag
9604
PMU 1 Ia Angle
9605
PMU 1 Ib Mag
9607
PMU 1 Ib Angle
9608
PMU 1 Ic Mag
9610
PMU 1 Ic Angle
9611
PMU 1 Ig Mag
9613
PMU 1 Ig Angle
9614
PMU 1 I1 Mag
9616
PMU 1 I1 Angle
9617
PMU 1 I2 Mag
9619
PMU 1 I2 Angle
9620
PMU 1 I0 Mag
9622
PMU 1 I0 Angle
9623
PMU 1 Freq
9625
PMU 1 df dt
9626
PMU 1 Conf Ch
9631
PMU 2 Va Mag
9633
PMU 2 Va Angle
9634
PMU 2 Vb Mag
9636
PMU 2 Vb Angle
9637
PMU 2 Vc Mag
9639
PMU 2 Vc Angle
9640
PMU 2 Vx Mag
9642
PMU 2 Vx Angle
9643
PMU 2 V1 Mag
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
UNITS
DESCRIPTION
Degrees
Synchrocheck 2 delta phase
Volts
Synchrocheck 3 delta voltage
Hz
Synchrocheck 3 delta frequency
Degrees
Synchrocheck 3 delta phase
Volts
Synchrocheck 4 delta voltage
Hz
Synchrocheck 4 delta frequency
Degrees
Synchrocheck 4 delta phase
Volts
Phasor measurement unit 1 phase A voltage magnitude
Degrees
Phasor measurement unit 1 phase A voltage angle
Volts
Phasor measurement unit 1 phase B voltage magnitude
Degrees
Phasor measurement unit 1 phase B voltage angle
Volts
Phasor measurement unit 1 phase C voltage magnitude
Degrees
Phasor measurement unit 1 phase C voltage angle
Volts
Phasor measurement unit 1 auxiliary voltage magnitude
Degrees
Phasor measurement unit 1 auxiliary voltage angle
Volts
Phasor measurement unit 1 positive-sequence voltage magnitude
Degrees
Phasor measurement unit 1 positive-sequence voltage angle
Volts
Phasor measurement unit 1 negative-sequence voltage magnitude
Degrees
Phasor measurement unit 1 negative-sequence voltage angle
Volts
Phasor measurement unit 1 zero-sequence voltage magnitude
Degrees
Phasor measurement unit 1 zero-sequence voltage angle
Amps
Phasor measurement unit 1 phase A current magnitude
Degrees
Phasor measurement unit 1 phase A current angle
Amps
Phasor measurement unit 1 phase B current magnitude
Degrees
Phasor measurement unit 1 phase B current angle
Amps
Phasor measurement unit 1 phase C current magnitude
Degrees
Phasor measurement unit 1 phase C current angle
Amps
Phasor measurement unit 1 ground current magnitude
Degrees
Phasor measurement unit 1 ground current angle
Amps
Phasor measurement unit 1 positive-sequence current magnitude
Degrees
Phasor measurement unit 1 positive-sequence current angle
Amps
Phasor measurement unit 1 negative-sequence current magnitude
Degrees
Phasor measurement unit 1 negative-sequence current angle
Amps
Phasor measurement unit 1 zero-sequence current magnitude
Degrees
Phasor measurement unit 1 zero-sequence current angle
Hz
Phasor measurement unit 1 frequency
Hz/s
Phasor measurement unit 1 rate of change of frequency
---
Phasor measurement unit 1 configuration change counter
Volts
Phasor measurement unit 2 phase A voltage magnitude
Degrees
Phasor measurement unit 2 phase A voltage angle
Volts
Phasor measurement unit 2 phase B voltage magnitude
Degrees
Phasor measurement unit 2 phase B voltage angle
Volts
Phasor measurement unit 2 phase C voltage magnitude
Degrees
Phasor measurement unit 2 phase C voltage angle
Volts
Phasor measurement unit 2 auxiliary voltage magnitude
Degrees
Phasor measurement unit 2 auxiliary voltage angle
Volts
Phasor measurement unit 2 positive-sequence voltage magnitude
A.1 PARAMETER LISTS
A-11
A

Hide quick links: