1800Gh Gas Tips - Broaster 1600 Operation Manual

Pressure fryer
Hide thumbs Also See for 1600:
Table of Contents

Advertisement

1800GH GAS TIPS

COMPLAINT
Pilot burner won't ignite
Pilot goes out when button
is released
Main burner won't ignite
CAUSE
1. Gas valve OFF
2. Air in pilot gas line
3. Gas shut-off valve OFF
1. Button not held in long
enough
2. Hi-limit tripped
1. Pilot burner not lit
2. Gas control OFF
3. Gas control on PILOT
4. Controller in program
mode
5. Cook/filter switch OFF
6. Hi-limit tripped
14 - 3
Manual #13897 10/97
REMEDY
1. Turn to PILOT
2. See MODEL 1800GH
LIGHTING INSTRUC-
TIONS
3. Turn ON
1. See MODEL 1800GH
LIGHTING INSTRUC-
TIONS
2. Turn cook/filter switch
OFF. Contact service
person.
1. See MODEL 1800GH
LIGHTING INSTRUC-
TIONS
2. Turn ON
3. Turn ON
4. Exit program mode
5. Turn to COOK
6. Turn cook/filter switch
OFF. Contact service
person.