Control Change
status
2nd byte
3rd byte
BnH
kkH
vvH
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
kk=control number
: 00H - 78H (0 - 120)
vv=value
: 00H - 7FH (0 - 127)
* This message is not received if the Ctrl Change parameter (Rec Select win-
dow) is OFF.
Program Change
status
2nd byte
CnH
ppH
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
pp=Program number
: 00H - 7FH (prog.1 - prog.128)
* This message is not received if the Prog Change parameter (Rec Select
window) is OFF.
Channel Aftertouch
status
2nd byte
DnH
vvH
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
vv=Channel Aftertouch
: 00H - 7FH (0 - 127)
* This message is not received if the Channel Aft parameter (Rec Select win-
dow) is OFF.
Pitch Bend Change
status
2nd byte
3rd byte
EnH
llH
mmH
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
mm,ll=Pitch Bend value
: 00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
* This message is not received when the Pitch Bend parameter (Rec Select
window) is OFF.
Channel Mode messages
All Sound Off (Controller number 120)
status
2nd byte
3rd byte
BnH
78H
00H
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
Reset All Controllers (Controller number 121)
status
2nd byte
3rd byte
BnH
79H
00H
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
Omni Off (Controller number 124)
status
2nd byte
3rd byte
BnH
7CH
00H
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
* The same processing will be done as when an All Note Off message is
received.
Omni On (Controller number 125)
status
2nd byte
3rd byte
BnH
7DH
00H
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
* The same processing will be done as when an All Note Off message is
received.
Mono (Controller number 126)
status
2nd byte
3rd byte
BnH
7EH
mmH
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
mm=mono number
: 00H - 10H (0 - 16)
* The same processing will be done as when an All Note Off message is
received.
Poly (Controller number 127)
status
2nd byte
3rd byte
BnH
7FH
00H
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
* The same processing will be done as when an All Note Off message is
received.
220
Chapter 12. Supplementary material
System Exclusive messages
status
data byte
status
F0H
iiH, ddH, ......, eeH
F0H
: System Exclusive message status
ii = ID number
: This is the ID number (manufacturer ID) that
specifies the manufacturer whose exclusive mes-
sage this is. Roland's manufacturer ID is 41H.ID
numbers 7EH and 7FH are defined in an expan-
sion of the MIDI standard as Universal Non-real-
time messages (7EH) and Universal Realtime
Messages (7FH).
dd,..., ee = data
: 00H - 7FH (0 - 127)
F7H
: EOX (End Of Exclusive)
* These messages are not received if the Sys.Excl parameter (Rec Select
window) is OFF.
3.2 Messages not recorded during recording
Channel Mode messages
Local On/Off (Controller number 122)
status
2nd byte
3rd byte
BnH
7AH
00H
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
vv=value
: 00H,7FH (Local off, Local on)
All Note Off (Controller number 123)
status
2nd byte
3rd byte
BnH
7BH
00H
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
* When an All Note Off message is received, all notes of the corresponding
channel that are on will be sent Note Off's, and the resulting Note Off mes-
sages will be recorded.
3.3 Messages acknowledged for synchronization
System Common messages
Song Position Pointer
status
2nd byte
3rd byte
F2H
mmH
llH
mm,ll=value: 00 00H - 7F 7FH (0 - 16383)
Song Select
status
2nd byte
F3H
ssH
ss=value
: 0 - 7FH (0 - 127)
* This message can be received when the sequencer is stopped. It will not
be received while in the Edit display or Microscope display.
System Realtime messages
Timing Clock
status
F8H
* This message will be received if the Sync Mode parameter (SEQUENCER/
Setup/SEQ System Setup) is SLAVE.
Start
status
FAH
* This message will be received if the Sync Mode parameter (SEQUENCER/
Setup/SEQ System Setup) is SLAVE or REMOTE.
Continue
status
FBH
* This message will be received if the Sync Mode parameter (SEQUENCER/
Setup/SEQ System Setup) is SLAVE or REMOTE.
Stop
status
FCH
* This message will be received if the Sync Mode parameter (SEQUENCER/
Setup/SEQ System Setup) is SLAVE or REMOTE.
F7H