Furuno IC-307 Operator's Manual page 22

Ship security alert system (ssas) uscg version
Table of Contents

Advertisement

Options
1. Login
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test
Distress/SSAS buttons are under test mode.
5. Ocean Region
4. Distress Alarm Button Test
INF: SSAS Buttons entered into TEST MODE.
6. Test
The display shows the message (in red) "Distress/SSAS buttons are under test. Cancel
the test mode if a real distress/SSAS needs to sent." appears.
5. Open the button cover on the No.1 SSAS.
6. Push the button. The CAUTION window displays the message "SSAS UNIT works
correctly." appears if the unit is functioning properly.
7. Five seconds after pressing the button the SSAS test report is automatically sent to
station whose Mode set on the SSAS Report window is "Real+Test" or "Test Only".
Note: To test the No. 2 and No. 3 SSAS press appropriate button.
8. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.
9. Press the [Esc] key three times to return to the standby display.
Test
Distress/SSAS Button Test
CAUTION
Press any key to escape.
<Press ESC key to continue>
CAUTION
<Press ESC key to continue>