Wiring; Junction Box (For Felcom 16/19) - Furuno IC-307 Operator's Manual

Ship security alert system (ssas) uscg version
Table of Contents

Advertisement

2.2 Wiring

2.2.1 Junction box (for FELCOM 16/19)

Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16, or the
junction box IC-318 to connect the SSAS alert unit to the FELCOM 19. Unfasten four
screws to remove the cover to connect cables to terminal board. For detailed wiring
information see the interconnection diagram.
For connecting the SSAS alert unit IC-307, use the JIS cable TTYCS-4 (or equivalent, see
next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the
CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp
16-018-6008-1, supplied with the junction box. For connecting the communication unit
IC-216, use cable 16S0344.
Terminal
board
Communication
Unit
Cable clamp
16S0344
Connect the drain wire of the TTYCSLA cables
with the screw and crimp-on lugs provided.
IC-318 (inside)
Cover
Cable clamp
(top)
Cable clamp
(bottom)
Fold back braided shield onto
sheath and fix by cable clamp.
15mm
90mm
7mm
Screw, crimp-on lug
(pre-fitted at factory)
6
IC-315
IC-318
1
Vcc
1
Vcc
2
2
GND
GND
3
TD/RD-A
3
TD/RD-A
4
4
TD/RD-B
TD/RD-B
5
NC
5
NC
6
TD-A(NAV)
6
ALM-H
7
7
TD-B(NAV)
ALM-C
8
RD-A(NAV)
8
RD-A(NAV)
9
9
RD-B(NAV)
RD-B(NAV)
10
GND
10
GND
11
11
DMC OUT-H
SSAS OUT-H
12
12
DMC OUT-C
SSAS OUT-C
13
DMC IN-H
13
SSAS IN-H
14
14
DMC IN-C
SSAS IN-C
15
DMC CTR
15
SSAS CTR
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
Note 1: Do not insert the cable too
deeply, to prevent pinching the sheath.
Note 2: Pull each cable slightly to con-
firm that they are in their holes securely.
1
2
3
Core 7 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Felcom 15Felcom 16Felcom 18Felcom 19

Table of Contents