Ship security alert system (ssas) uscg version
Table of Contents

Advertisement

2.2.2 SSAS alert unit

Three SSAS alert units can be connected. For wiring, see the illustrations below and the
interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15/18)
and the communication unit (FELCOM 16/19), the wiring of the SSAS is monitored and if in
error "TROUBLE: SSAS UNIT connection abnormality." is displayed. Further the ERROR
lamp (FELCOM 16) flashes.
Connect wiring to the terminal board 16P0229 inside the SSAS alert unit. To differentiate
between units in case of multiple unit installation, change jumper block settings as shown
below, in accordance with how many units are installed.
Jumper settings for two IC-307
Unit
Jumper
JP1
JP2
No. 1 unit: Unit with two cables connnected to it.
No. 2 unit: Unit with one cable connnected to it.
Two IC-307: No. 2 unit
Three IC-307: No. 3 unit
16P0229
JP1
JP2
1 2
3 4 5 6
IC-307
Clamp for cable
CO-SPEVV-SB-C
0.2x5P
Clamp for cable
TTYCS-4
or equivalent
Junction
Box
IC-307
(No.1)
No.1 unit*
No. 2 unit
*: Default
No
Yes
Yes
No
Three IC-307: No. 1 and No. 2 units
16P0229
Wiring inside the SSAS alert unit
IC-307
(No. 2)
Jumper settings for three IC-307
Unit
No.1 unit*
Jumper
setting
No
JP1
JP2
Yes
No. 1 and No. 2 units: Units with two cables connnected to them.
No. 3 unit: Unit with one cable connnected to it.
Two IC-307: No. 1 unit
JP1
JP2
1 2
3 4 5 6
IC-307
Cable Fabrication
Twist shield.
CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
Cut and tape
unused wires
to prevent short.
 = 16.3
mm
Conductor
Sectional view of cable TTYCS-4
7
IC-307
(No. 3)
No. 2 unit*
No. 3 unit
No
Yes
Yes
No
15 mm 40 mm 10 mm
Armor
Sheath
Shield
2
S = 0.75 mm
 = 1.11 mm