Set Up Retransmission Page - ABB 4623 Manual

Conductivity transmitters 4600 series
Table of Contents

Advertisement

...7 PROGRAMMING

7.5 Set Up Retransmission Page

– – – – –
SET UP RETRANS
– – – – –
Set Up Retrans 1
– – – – –
RTX Type
4-20
0-20
0-10
1 0 0 . 0
µS/cm
RTX Span
20
– press to advance to next parameter
or
– press to advance to next page.
These two keys are used to advance to all subsequent parameters and pages. If a
parameter is changed it is automatically stored on operation of either key.
Set Up Retransmission 1
Retransmission 1 Output Range
Set the retransmission output current range for retransmission channel 1.
Retransmission 1 Span
Set the required span over which the retransmission output is to operate to between 10
and 100% of the display span – see Section 7.3,
Continued on next page.
.