Tesla WALL CONNECTOR Installation Manual page 25

32a three phase
Hide thumbs Also See for WALL CONNECTOR:
Table of Contents

Advertisement

Green
Yellow
Lights
Light
Off
Off
Off
Off
Top light
Off
on
Top light
Off
on
Top light
Off
on
Troubleshooting
Red Light
Auto-Retry
5 flashes
After 1
minute retry
(no limit on
retries)
6 flashes
After 1
minute retry
(no limit on
retries)
1 flash
No
2 flashes
No
3 flashes
No
Troubleshooting
What it Means
What to Do
Over current
Reduce the vehicle's
protection.
charge current
setting. If the problem
persists and the
attached vehicle is
manufactured by
Tesla, contact Tesla. If
the problem persists
and If the attached
vehicle is not
manufactured by
Tesla, contact the
original manufacturer.
A communication
If possible, plug the
error occurred
vehicle into another
between the Wall
Wall Connector or a
Connector and the
Mobile Connector to
vehicle.
determine if the
vehicle is able to
communicate with
other charging
equipment. Then
contact Tesla Service.
Over temperature
Make sure the Wall
protection (latch-
Connector, vehicle
off)
connectors, and wall
plug (if used) are not
covered by anything
and there is no heat
source nearby. If the
problem persists in
normal ambient
temperatures (under
38°C), contact Tesla.
Non-Tesla vehicle
Compatible input
attempting
distributions are:
connection to non-
single-phase
compatible input
distribution or 400V,
distribution.
three-phase
distribution.
Incorrect rotary
Consult your
switch setting.
electrician.
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents