Set The Operating Current - Tesla WALL CONNECTOR Installation Manual

32a three phase
Hide thumbs Also See for WALL CONNECTOR:
Table of Contents

Advertisement

Set the Operating Current

Follow these instructions to configure the DIP
switch. The following illustration shows an
enlarged view of the DIP and rotary switches.
Warning: Power MUST remain OFF before
setting or changing the DIP or rotary
switches. Changing these switches with
the power ON will not be recognized by
the system and is dangerous due to the
risk of electric shock.
1.
Turn OFF power.
2.
Use a non-conductive object to adjust the
DIP switch settings:
Switch Position 1:
If the grounding scheme is TN or
TT, set the DIP switch DOWN.
If the grounding scheme is IT, set
the DIP switch UP (the ON
position).
Warning: Before you set the DIP
switches, confirm which type of
input service the utility provides.
Switch Position 2:
DIP Switch Position 2 should
always be in the UP position.
Step-by-Step Installation Instructions
Step-by-Step Installation Instructions
3.
Wiring/Connection
DIP Switch
Position
IT
TT-TN
Set the rotary switch for the appropriate
current setting supported by your circuit
breaker. Typical circuit breaker ratings are:
6A, 8A, 10A, 13A, 16A, 20A, 25A and 32A.
Use a small flathead screwdriver to adjust
the rotary switch to the appropriate circuit
breaker capability setting. The
corresponding rotary switch settings for
the typical circuit breakers are shown in
the following table:
19