Page 1
WALL CONNECTOR, 40A SINGLE PHASE INSTALLATION MANUAL THIS MANUAL IS OF THE HIGHEST IMPORTANCE Approved Markets: China Mainland, Hong Kong 壁挂式连接器, 40A 单相电流 安装手册 该手册至关重要 经批准的市场:中国大陆地区和香港地区 壁掛式連接器, 40A 單相電流 安裝手冊 本手冊至關重要 經核準的市場:中國大陸地區和香港地區 WALL CONNECTOR, 40A SINGLE PHASE INSTALLATION MANUAL THIS MANUAL IS OF THE HIGHEST IMPORTANCE...
Page 3
WALL CONNECTOR, 40A SINGLE PHASE INSTALLATION MANUAL China, Hong Kong...
Page 4
All information in this document and all MODEL S® software is subject to copyright and other intellectual property rights of Tesla Motors, Inc. and its licensors. This material may not be modified, reproduced or copied, in whole or in part, without the prior written permission of Tesla Motors, Inc. and its licensors. Additional information is available upon request.
CONNECTOR. FAILURE TO DO SO OR TO FOLLOW ANY OF THE INSTRUCTIONS AND WARNINGS IN THIS DOCUMENT CAN RESULT IN FIRE, ELECTRICAL SHOCK, SERIOUS INJURY OR DEATH. THE WALL CONNECTOR MUST BE INSTALLED BY A DULY REGISTERED AND QUALIFIED ELECTRICIAN, AND IN ACCORDANCE WITH LOCAL REGULATIONS AND ORDINANCES GOVERNING ELECTRICAL APPLIANCES AND THEIR INSTALLATION, USE, AND MAINTENANCE.
Store the charge handle above the ground to removing the power entry knock-out. prevent unnecessary exposure to contamination or moisture. Stop using and do not use the Wall Connector if it is defective, appears cracked, frayed, broken, or otherwise damaged, or fails to operate, or continue operation.
Specifications The maximum rating for the Wall Connector is 10 kW or 40 amps at 220 volts. Your vehicle can charge from 180 to 265 volts. Voltage and Wiring 220V AC single-phase: LINE, NEUTRAL, and EARTH Current Maximum 50A circuit breaker...
OPTIONAL CIRCUIT RATINGS POWER OUTAGES For the fastest charging, using a circuit If a power outage occurs, the Wall Connector breaker rated for 50 amps is recommended. automatically resumes charging when power is restored. If the charging cable is plugged into...
Run 32 mm metal pipe and flame retardant conduit on the left side of a wall stud. The conduit fits into the opening on either the back or the left side of the Wall Connector as described on page 8. NEUTRAL...
Installation Overview TOOLS REQUIRED Before installing the Wall Connector, ensure you have the following tools: • Pencil or marker • Drill and 8 mm drill bit • T20 torx driver • Hole saw, 32 mm • Sharp knife or razor •...
Step One - Check Box Contents In addition to this Installation Guide, the shipping box contains the following components. If any components are damaged or missing, contact Tesla. Wall Connector Mounting assembly bracket M10 lag screws and washers (2) Earth wire...
The height of the bracket should retardant conduit into either the back or the ensure that the charging connector is left side of the Wall Connector’s main located at a maximum of 122 cm from enclosure. Regardless of the conduit opening floor level.
Using a T20 Torx driver, remove the two Disconnect the ground wire from the security screws from the bottom of the terminal block and push it out of the way Wall Connector. to avoid damaging it when completing the next step. Disconnect...
Use the supplied flange screws to fasten the mounting bracket as shown below. the connector onto the bracket. Use a ratchet wrench and 8 mm socket to Attach the ground wire, as shown below. tighten until snugly fitted. WALL CONNECTOR INSTALLATION GUIDE...
If you are uncertain about the type of power available at 2-5 mm the service panel, consult your local utility, or contact Tesla for assistance. 8 mm Turn off the power. 13-21 mm WARNING: RISK OF ELECTRIC...
Maximum Current Rating Supplied to Vehicle (Amps) (Amps) To determine the type of electrical breaker you need, examine the distribution panel/ circuit breaker box to identify the amperage switches available at the installation site. Test Mode WALL CONNECTOR INSTALLATION GUIDE...
Do not secure the front cover yet. Turn on the power. Hold the RESET button for five seconds. This button is located on the lower right side of the Wall Connector. RESET button is located on the lower...
Using a T20 torx driver, re-attach the two security screws that you removed from the bottom of the Wall Connector in “Step Three - Prepare for Installation” on page 8. Turn on the power.
Step Nine - Install the Cable Hanger YOU WILL NEED To ensure the screws are secure, apply additional turns after the screw head is • Cable Hanger, bracket, two screws and two against the bracket. wall anchors (included in the shipping box) •...
Troubleshooting Observe the lights on the front of the Wall Connector, then use the following table to resolve a fault. Green Lights Light What It Means What To Do Top light Power on. Wall Connector is Make sure the Wall Connector is powered, but not charging.
Wall Connector, its charging cable, or the vehicle’s charging port. CAUTION: To reduce the risk of electrical shock or equipment damage, do not allow liquid to enter the Wall Connector while cleaning it. CHINA MAINLAND, HONG KONG...
Page 63
WALL CONNECTOR, 40A SINGLE PHASE INSTALLATION MANUAL Australia...
Page 64
All information in this document and all MODEL S® software is subject to copyright and other intellectual property rights of Tesla Motors, Inc. and its licensors. This material may not be modified, reproduced or copied, in whole or in part, without the prior written permission of Tesla Motors, Inc. and its licensors. Additional information is available upon request.
Page 65
CONNECTOR. FAILURE TO DO SO OR TO FOLLOW ANY OF THE INSTRUCTIONS AND WARNINGS IN THIS DOCUMENT CAN RESULT IN FIRE, ELECTRICAL SHOCK, SERIOUS INJURY OR DEATH. THE WALL CONNECTOR MUST BE INSTALLED BY A DULY REGISTERED AND QUALIFIED ELECTRICIAN, AND IN ACCORDANCE WITH LOCAL REGULATIONS AND ORDINANCES GOVERNING ELECTRICAL APPLIANCES AND THEIR INSTALLATION, USE, AND MAINTENANCE.
Store the charge handle above the ground to removing the power entry knock-out. prevent unnecessary exposure to contamination or moisture. Stop using and do not use the Wall Connector if it is defective, appears cracked, frayed, broken, or otherwise damaged, or fails to operate, or continue operation.
Specifications The maximum rating for the Wall Connector is 10 kW or 40 amps at 240 volts. Your vehicle can charge from 180 to 265 volts. Voltage and Wiring 240V AC single-phase: LINE, NEUTRAL, and EARTH Current Maximum 50A circuit breaker...
OPTIONAL CIRCUIT RATINGS POWER OUTAGES For the fastest charging, using a circuit If a power outage occurs, the Wall Connector breaker rated for 50 amps is recommended. automatically resumes charging when power is restored. If the charging cable is plugged into...
240V RMS to neutral. Earth must also be connected to the Wall Connector. Conduit fits into the opening on either the back or the left side of the Wall Connector as described on page 8. The illustrations provided below shows the most commonly used wiring format.
(see pages 4 through 4), and installing the appropriate circuit breaker, TURN OFF THE POWER SUPPLY. Then follow these steps to install the Wall Connector: Check box contents (see page 6) Install wall bracket (see page 7) Prepare for installation (see page 8)
Step One - Check Box Contents In addition to this Installation Guide, the shipping box contains the following components. If any components are damaged or missing, contact Tesla. Wall Connector Mounting assembly bracket M10 lag screws and washers (2) Earth wire...
You can run conduit into either the back or the • The height of the bracket should left side of the Wall Connector’s main ensure that the charging connector is enclosure. Regardless of the conduit opening located at a maximum of 1.2 m from you use, always run the conduit on the left side floor level.
Using a T20 Torx driver, remove the two Disconnect the Earth wire from the security screws from the bottom of the terminal block and push it out of the way Wall Connector. to avoid damaging it when completing the next step. Disconnect...
Use the supplied flange screws to fasten the mounting bracket as shown below. the connector onto the bracket. Use a ratchet wrench and 8 mm socket to Attach the Earth wire, as shown below. tighten until snugly fitted. WALL CONNECTOR INSTALLATION GUIDE...
If you are uncertain about the type of power available at 6-12 mm the service panel, consult your local utility, or contact Tesla for assistance. 13-25 mm Turn off the power. WARNING: RISK OF ELECTRIC SHOCK! Before connecting the...
Maximum Current Rating Supplied to Vehicle (Amps) (Amps) To determine the type of electrical breaker you need, examine the distribution panel/ circuit breaker box to identify the amperage switches available at the installation site. Test Mode WALL CONNECTOR INSTALLATION GUIDE...
Do not secure the front cover yet. Turn on the power. Hold the RESET button for five seconds. This button is located on the lower right side of the Wall Connector. RESET button is located on the lower...
Using a T20 torx driver, re-attach the two security screws that you removed from the bottom of the Wall Connector in “Step Three - Prepare for Installation” on page 8. Turn on the power.
Step Nine - Install the Cable Hanger YOU WILL NEED To ensure the screws are secure, apply additional turns after the screw head is • Cable Hanger, bracket, two screws and two against the bracket. wall anchors (included in the shipping box) •...
Troubleshooting Observe the lights on the front of the Wall Connector, then use the following table to resolve a fault. Green Lights Light What It Means What To Do Top light Power on. Wall Connector is Make sure the Wall Connector is powered, but not charging.
Wall Connector, its charging cable, or the vehicle’s charging port. CAUTION: To reduce the risk of electrical shock or equipment damage, do not allow liquid to enter the Wall Connector while cleaning it. AUSTRALIA...
Need help?
Do you have a question about the WALL CONNECTOR and is the answer not in the manual?
Questions and answers