Connect the Wiring

Note: Consult with your local electrician or
refer to your local code for proper wire sizing
appropriate for the currents in your Wall
Connector.
Note: It is the installer's responsibility to
identify whether additional grounding is
required to ensure that local regulations are
met. Grounding must be installed at the power
source and not at the cable entry to the Wall
Connector.
Note: For three-phase wiring, connect the
terminal block with the L1, L2, L3, neutral, and
ground.
Warning: Do not connect service wiring
until you have read and fully understand
the concepts described in Service Wiring
on page 7.
1.
Turn off the power.
Warning: RISK OF ELECTRIC SHOCK!
Before continuing, use a voltmeter to
ensure the power is off by confirming
that NO VOLTAGE is present at the
service wiring or terminals.
2.
For top entry installation, pull the service
wiring into the top entry bracket or the
Wall Connector. Use an M32 cable gland
to seal the power conduit or cable.
Note: The meaning of wiring colors might
vary from country to country. Follow all
applicable national and local regulations
concerning wiring color codes.
Step-by-Step Installation Instructions
Step-by-Step Installation Instructions
3.
4.
The following illustration shows an
example of the wiring for the top entry
bracket.
The following illustration shows an
example of the wiring for the low profile
bracket.
Strip the service wires going to the
terminal block on the top entry bracket 8
mm. Ferrules are recommended.
Note: For top entry installation, the
flexible pre-installed wires that go from
the top entry bracket to the housing are
already terminated and do not need to be
stripped.
Lead the preconnected service wires in
the main housing and connect the
preconnected service wires to the main
terminal block (cross section: 10 mm,
diameter: 3.6 mm) with L1, L2, L3, neutral,
and ground wires going to the locations
shown in the following illustration.
Caution: Cut each of the wire strands
and insert them fully into each the
terminal block.