5.5 Turning Bluetooth ON

1. Rotate the rotary switch to the MR or Setup position.
2. Press and release the HOLD /
■ When Bluetooth (BT) is ON you will see a flashing Bluetooth icon ( ) at the
bottom of the display.
■ To turn Bluetooth OFF, repeat the steps given above.
■ Once Bluetooth is ON you can rotate the rotary switch to any position (except
OFF) and the Bluetooth will remain ON.

5.6 Turning the Instrument OFF

The instrument can be turned OFF in two ways:
■ Manually: Turn the rotary switch to OFF.
■ Auto Power OFF: This function activates after 5 minutes of no activity (no
button press, no change of switch setting, and no opening of the jaws).
- Fifteen seconds before Auto Power OFF, a short audible signal is emitted
and the display blinks once a second.
Auto Power OFF can be disabled in SET-UP (see § 4.4, menu #3). The
symbol is then displayed.

5.7 Standard and Advanced Modes

The instrument has two modes.
■ Standard Mode: Makes the standard loop resistance and leakage current
measurements.
■ Advanced Mode: Used to refine and complete the measurements:
- Impedance at the selected frequency.
- Contact voltage.
- Resistive and inductive components of the loop impedance.
The choice of Standard or Advanced mode and the alarm thresholds are
configured in SET-UP (see § 4.4, menu #9).