Wall-hung gas boiler for heating - high efficiency - modulating
Hide thumbs Also See for Xilo T 20 MS W TOP:

Advertisement

CERTIFICATED COMPANY ISO 9001
WALL-HUNG GAS BOILER FOR HEATING - HIGH EFFICIENCY - MODULATING
E S
A K
A L
E M
N U
A S
E U
M A
P L E
T H
S E
T O
" U
E R
O V
20 MS W TOP
INSTALLATION AND MAINTENANCE MANUAL
H E
T T
H A
D
E T
D E
U R
A N
S H
" I
R
S E
/IE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xilo T 20 MS W TOP and is the answer not in the manual?

Questions and answers

Summary of Contents for Lamborghini Caloreclima Xilo T 20 MS W TOP

  • Page 1 CERTIFICATED COMPANY ISO 9001 " I P L E " U WALL-HUNG GAS BOILER FOR HEATING - HIGH EFFICIENCY - MODULATING 20 MS W TOP INSTALLATION AND MAINTENANCE MANUAL...
  • Page 3 IRISH Read carefully all warning and instructions contained in this manual at they give important safety instructions regarding installation and maintenance. Keep this manual for future reference. Installation must be carried out by qualified personnel who will be responsible for respecting existing safety regulations.
  • Page 4: Table Of Contents

    ..on an excellent choice. We thank you for the preference accorded to our products. LAMBORGHINI CALORECLIMA has been actively present in Italy and throughout the world since 1959 with a widespread network of agents and concessionary agents to constantly guarantee the presence of our product on the market.
  • Page 5: General Instructions

    GENERAL INSTRUCTIONS G This booklet constitutes an integral and essential part of the product. Read carefully the instructions contained in this booklet as they provide important directions regarding the safety of installation, use and maintenance. Preserve this booklet with care for any further consultation. The installation of the boiler must be carried out in compliance with current regulations, according to the instructions of the manufacturer and by qualified personnel.
  • Page 6: Description

    Hot water plate exchanger. XILO T 20 MS W TOP Equipped with electronic control unit for automatic ignition and ionization electrode flame control. To ensure safe operation, the electric fan is controlled by a pressure switch.
  • Page 7: Main Components

    MAIN COMPONENTS XILO T 20 MS W TOP 14 13 1009DIS1357 LEGEND Automatic air bleed valve 17 Thermohydrometer Fumes pressure switch 10 Safety valve 18 Malfunction warning light Heating sensor 11 Circulator 19 ON/OFF warning light 12 Filling cock 20 Lock-out warning light...
  • Page 8: Dimensions

    DIMENSIONS mm XILO T 20 MS W TOP Max. 3000 Max. 3000 TECHNICAL FEATURES Operating Expansion Connections Weight Thermal capacity Min. thermal capacity tank pressure max. MODEL Main system Cold water Input Output Input Output inlet Return Supply kW kcal/h kW kcal/h...
  • Page 9: Gas - Nozzle Calibration

    GAS - NOZZLE CALIBRATION The boilers leave the factory calibrated and ready to operate with NATURAL GAS and LIQUID GAS. For proper calibration, see the table below: Jets pressure mbar Burner Gas type Delivery L.C.V. XILO T 20 MS jets min.
  • Page 10: Electrical Connections - Wiring Diagrams

    ELECTRICAL CONNECTIONS - WIRING DIAGRAMS The boiler must be connected to an earthed, single-phase 230V-50 Hz mains supply by means of a three-wire cable, ensuring that connections to the LINE and NEUTRAL terminals are made correctly. A bipolar switch must be used with contacts opening to at least 3 mm. The power lead must only be replaced by another with the following characteristics: “HAR H05 VV-F”...
  • Page 11 ASSEMBLY DIAGRAM XILO T 20 MS W TOP JUMPER TO BE CUT IF LIMIT THERMOSTAT IS REQUIRED JP5 (LOW TEMP.) R max. PANEL CONNECTION Lock-out warning light ON/OFF warning light Malfunction warning light CONTROL PANEL LEGEND BM Modulating coil Line 230 V 50 Hz...
  • Page 12: Malfunctions And Adjustments

    MULFUNCTIONS AND ADJUSTMENTS Constant light: Ignition shutdown Constant light: No water Fast flashing light: Sensor fault Fast flashing light: TST shutdown Slowly flashing light: Air pressure switch (MS) Should the boiler shut down it must be reset by rotating functions selector switch to position A. Legend: J P 3 J P 1...
  • Page 13: Water Connection

    WATER CONNECTION Fit the supporting hooks and attach the assembly template, moving it up to the wall; fit all the pipes, starting with the end pipe fittings already mounted on the template: system supply, system return, cold water, hot water, any gas pipes and electric mains leads with room thermostat.
  • Page 14: Water Circuit

    WATER CIRCUIT XILO T 20 MS W TOP LEGEND System delivery No-water pressure switch Circulator Cold water inlet Burner System return Expansion tank Exchanger Fumes pressure switch Modulator coil Heating sensor Automatic air bleed valve Gas valve Total safety thermostat...
  • Page 15: Boiler Installation

    BOILER INSTALLATION UNPACKING THE BOILER Open the top of the carton and remove the following parts: Boiler tools and accessory pack Document pack and wall template Wall mounting template Down-draft diverter Break open the boiler carton with care. Do not cut the carton, open with a knife: you could damage the jacket.
  • Page 16: Installation

    INSTALLATION To be carried out by qualified personnel. The installation must be in compliance with the stipulations of the law regarding the evacuation of combustion materials according to the REGULATIONS IN FORCE. The gas fume evacuation must be effected with a pipe of a diameter not less than that required by the boiler and it must be connected to a flue pipe suitable for the capacity of the installation.
  • Page 17: Flue Exhaust Connection

    FLUE EXHAUST CONNECTION CONNECTION TO THE CHIMNEY - VERSION XILO T 20 MS W TOP The boiler is for combustion in a sealed chamber and does not require any special ventilation, it can also be located in small rooms, lumber-rooms, laboratories. In addition, there are various possibilities for combustion fume evacuation and external air intake;...
  • Page 18: Flue Exhaust Installation

    ELBOW FITTED ELBOW FITTED TYPE OF INSTALLATION AT 90° AT 45° 1 mt. 0,5 mt. CONCENTRIC FLUE PIPE 0,6 mt. 0,3 mt. SEPARATE INTAKE/EXHAUST ** Air intake Ø 80 ATTENTION: Use only air intake/ fume evacuation kits produced by Lamborghini Caloreclima.
  • Page 19: Adjustments

    ADJUSTMENTS The boilers have a fast opening gas valve. The necessary calibration for gas delivery may be obtained from a double modulator coil. Calibration of the slow ignition (pre-calibrated in the factory) is electronically done and is adjustable (for optimising and for gas type conversion) by the trimmer RLA on the electronic board. The necessary thermal output for the heating system can be regulated by manipulating the trimmer R MAX.
  • Page 20: Switching Off

    SWITCHING OFF PROLONGED SWITCHING OFF If the boiler should remain inactive at length close the gas cock and cut electrical power supply to the appliance. TEMPORARY SWITCHING ON/OFF Proceed in one of the following ways: G use the room thermostat; G use the adjustment potentiometers (on the instrument panel);...
  • Page 21 removal of any oxidation from burners removal of any encrustation from heat exchangers checking and general cleaning of fan checking connections between the various air/fume pipes general pipe cleaning checking general external appearance of boiler checking for proper ignition, shutdown and operation of both hot water and heating functions checking for proper seal on gas/water fittings and pipes.
  • Page 22: Operation With Different Types Of Gas

    OPERATION WITH DIFFERENT TYPES OF GAS CONVERSION FROM NATURAL GAS TO LIQUID GAS Proceed with burner jets replacement, insert the diaphragm as illustrated in the diagram included with the kit. Shift bridge JP1 on the modulation board from the NATURAL GAS position to the B-P position. Then proceed with proper adjustment as described in the “ADJUSTMENT”...
  • Page 23: Fault-Finding Chart

    FAULT-FINDING CHART FAULT CAUSE REMEDY 1 NO IGNITION A. Gas cock closed A. Open gas cock B. Boiler locked out B. Reset by pressing C. No flame detection C. Neutral and phase inverted D. No ignition spark D. Call technical service E.
  • Page 28 BURNERS WALL HUNG AND FLOOR STANDING GAS BOILERS CAST IRON AND STEEL BOILERS WARM AIR HEATERS WATER TREATMENT AIR CONDITIONING Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene più...