Summary of Contents for Lamborghini Caloreclima Taura 24 MCS W TOP
Page 1
CALDERA MURAL DE GAS CON CÁMARA ESTANCA PARA AGUA SANITARIA Y CALEFACCIÓN CALDEIRA MURAL A GÁS CÂMARA ESTANQUE, PARA PRODUÇÃO DE ÁGUA QUENTE SANITÁRIA E AQUECIMENTO ΕΠΙΤΟΙΧΟΣ ΛΕΒΗΤΑΣ ΑΕΡΙΟΥ ΣΤΕΓΑΝΟΎ ΘΑΛΆΜΟΥ, ΓΙΑ ΖΕΣΤΌ ΝΕΡΌ ΚΑΙ ΘΈΡΜΑΝΣΗ TAURA 24 MCS W TOP cod. 3540D95/0 ediz. 06/2006 ISTRUZIONI PER...
Taura 24 MCS W TOP • This instruction booklet is an integral part of the • This unit must only be used for the purpose for product and must be carefully kept by the user for which it was designed. Any other use is considered future reference.
TAURA 24 MCS W TOP is a high-efficiency heat generator for heating and hot water production running on natural or liquefied petroleum gas, equipped with an open-flue burner with electronic ignition, airtight chamber with forced ventilation and a microprocessor control system.
Taura 24 MCS W TOP 1.3 Turning on and off Ignition • Open the gas valve ahead of the boiler. • Supply the unit with electricity. Turn the selector 3 onto (winter) or onto (summer) • Turn the heating and hot water knob onto the required temperatures.
Taura 24 MCS W TOP If the unit is enclosed in furniture or mounted alongside, there must be space for removing the casing and for normal maintenance work. 2.3 Plumbing connections The heating capacity of the unit should be previously established by calculating the building’s heat requirement ac- cording to current regulations.
Taura 24 MCS W TOP 2.5 Electrical Connections Connection to the electrical grid The boiler must be connected to a single-phase, 230 Volt-50 Hz electric line. The unit’s electrical safety is only guaranteed when correctly connected to an efficient earthing system executed according to current safety standards.
Page 7
Taura 24 MCS W TOP Diaphragms Boiler operation requires fitting the diaphragms supplied with the unit as instructed in the following tables and drawings. Choosing the diaphragm using coaxial pipes Choosing the diaphragm using separate pipes Pipe length Type Length up to:...
Page 8
Remove the air inlet closing cap. Fit the two flanged sections Ø80, with their seals. If necessary, install the diaphragm under the air inlet section Remove Fumes the plug Air diaphragm ** Air suction Ø 80 Caution: use solely Lamborghini Caloreclima fume suction/outlet kits...
Taura 24 MCS W TOP 3. SERVICE AND MAINTENANCE All adjustment, conversion, system start-up and maintenance operations described hereunder must be carried out solely by Qualified Personnel such as the personnel of the Local After-Sales Technical Service. LAMBORGHINI declines any responsibility for damage or physical injury caused by unqualified and unauthorized persons tampering with the device.
Page 10
Taura 24 MCS W TOP • Check that the maximum pressure has not changed. • Reconnect the pressure compensation tube “H”. • Put the protective cap “D” back on. • To end TEST mode, select another mode. Pressure point Modureg cable...
Page 11
Taura 24 MCS W TOP Entry Turn the Heating Installer Parameters Knob menu to exit the menu (Automatic exit Selector turned to “Reset” for after 2 minutes of knob 10 seconds: turn to “Winter” when inactivity) the 3 LEDs blink fast Select turned to PARAMETER No.
Page 12
Taura 24 MCS W TOP After establishing the parameter to be set, use the following conversion tables to understand the value being set, ac- cording to the blinking of the LEDs. OFF means LED off, ON means LED on, whereas ON BL means LED blinking.
Taura 24 MCS W TOP 3.2 System start-up Checks to be made at first ignition, and after all maintenance operations that involved disconnecting from the systems or an intervention on safety devices or parts of the boiler: Before lighting the boiler: •...
Taura 24 MCS W TOP Opening the casing To open the boiler casing: 1 Unscrew the four screws A 2 Lower the inspection door 3 Raise and remove the casing B Before carrying out any operation inside the boiler, disconnect the electrical power supply and close the gas cock upstream.
Taura 24 MCS W TOP 3.4 Troubleshooting Fault Diagnosis The boiler is equipped with an advanced self-diagnosis system. In the event of trouble with the boiler, the 3 LEDs will indicate the code of the fault. There are faults that cause shutdown: in order to restore operation it suffices to turn the selector (ref. 3 - fig. 1)
Taura 24 MCS W TOP 4 TECHNICAL CHARACTERISTICS AND DATA 4.1 Dimensions and connections Top view If using the LEJ LINE plumbing kit, the distances for drilling the wall are those given on the paper template contained in the kit...
Taura 24 MCS W TOP 4.2 General view and main components Fig. 7 Airtight chamber Combustion chamber Modureg Gas inlet insulation Safety thermostat Tap water outlet Copper exchanger for heating Expansion tank Tap water inlet and hot water Heating system cock...
Taura 24 MCS W TOP 4.3 Technical data table Powers Pmax Pmin Heating Power (Net Heat Value - Hi) 25,8 Available Thermal Power 80°C - 60°C 24,0 Hot Water Heating Power 24,0 Energy marking (92/42EEC directive) NOx emission class Gas supply...
Page 20
BRUCIATORI CALDAIE MURALI E TERRA A GAS GRUPPI TERMICI IN GHISA E IN ACCIAIO GENERATORI DI ARIA CALDA TRATTAMENTO ACQUA CONDIZIONAMENTO Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene più...