The AC power inverter is only 115V. The AC power inverter uses battery
power, so the batteries may require more frequent charging.
Remove ALL fuses from the cables before connecting ANY
cables to the batteries or switch. Make sure all the DC
connections are tight (torque to 9-10 ft-lbs, 11.7-13 Nm).
Loose connections overheat and could result in a potential
Check the wiring for your batteries and charger.
BAT 1
Green Wire
Ground to Station Floor
Make sure the proper voltage fuse is installed in each fuse holder.
Each fuse is labeled as 20A or 30A.
The batteries are connected with a 30 Amp fuse
BAT2 has a 20 Amp fuse from it to the terminal block.
WARNING
hazard.
30 Amp
Fuse Jumper
Connect, F2
BAT 2
Red Stripe Wire
to Terminal
Red Wire to
Inverter
20 Amp
Fuse, F1
Black
Wire (-) to
Terminal
Block
Red Wire to
Terminal Block