Charger; Inverter - Avery Dennison Mobile Work Station (MWS) Monarch 9876 Operating & Maintenance Instructions

Mobile work station
Hide thumbs Also See for Mobile Work Station (MWS) Monarch 9876:
Table of Contents

Advertisement

C h a r g e r
Input
Output
Electronic reverse polarity and short circuit-shutdown
Low voltage start (total battery voltage must be greater than 1V to
charge)
AC input fuse in AC input connector
Use only NRTL-listed accessories (National Recognized
I n v e r t e r
Input Voltage
No Load Current
Frequency
Output Voltage
Output Power
Surge Power
Output Waveform
Typical Effeciency
Operating
Temperature
A-2 Specifications
117VAC 60Hz, 320VA (Volt Amps)
24 Volts, 8 Amps DC
Testing Lab).
21 to 30VDC
0.23A
60 Hz
110VAC +5%
300W RMS (continuous)
400W RMS (1 second)
Pure Sine Wave (THD<4%)
75%
32°F to 105°F (0°C to 40°C)