1 1 - 2 0
EXHAUST SYSTEM AND INTAKE MANIFOLD
BR
ADJUSTMENTS (Continued)
DIAL
INDICATOR
REGULATED
AIR P R E S S U R E
J9411-16
Fig, 44 Wastegate and Dial
Indicator
(3) To adjust the wastegate linkage, apply air pres
sure to the actuator to release the spring tension on
the lever. Remove the control rod from the wastegate
lever (Fig. 45). P u l l the wastegate lever toward the
actuator (closed position).
(4) Adjust the length of the clevis end of the con
trol rod to align the clevis pin hole to the wastegate
lever. I n s t a l l the adjusting l i n k and retaining clip
(Fig. 45).
CAUTION:
DO NOT pull, push or force the align
ment of the clevis pin.
(5) After the adjustment is complete, tighten the
actuator rod j a m nut.
(6) Recheck the travel on the wastegate control
rod. Adjust, i f necessary.
CONTROL
ROD
WASTEGATE ACTUATOR
J9411-17
Fig. 45 Adjustment of Wastegate Actuator