6. Log back in to the standby CP blade and run firmwaredDownloadStatus on the
7. If you are upgrading through several levels of the Fabric OS, repeat step 2
8. Log out of the standby CP blade and log in to the active CP blade.
9. Proceed to "Completing the CP8 blade replacement" on page 98

Downloading firmware from a USB device

For this task, refer to Table 14 on page 94 for the correct sequence of upgrading
firmware versions to reach your target version. Complete the following steps to
download the firmware from a USB device.
This section assumes that the new firmware has already been copied onto the USB
device. The folder structure on the USB device must be as follows in order to allow
the device to be enabled:
brocade>
The firmware folder contains the folder for the specific release you are installing.
96
SAN768B-2 Installation, Service, and User Guide
standby CP blade to validate a successful commit. This may take up to 10
minutes.
through step 6 as often as necessary to complete the upgrade. Otherwise,
proceed to step 8.
config
firmware
firmwareKey
support
1. Insert the USB device into the USB port of the active CP blade.
2. Attach a serial cable from the PC to the active CP blade.
3. Log in to the active CP blade as admin if you are not still logged in and enter
usbStorage -e to enable the USB device.
4. Remove the serial cable from the active CP blade and attach it to the standby
CP blade and log in as admin.
5. Run firmwareDownload -s -U vX.X.X (where X.X.X is the firmware version
you are downloading) to download the firmware to the standby CP blade.
The -s option also disables the autoreboot, so you will have to manually issue
a reboot after the download finishes to initiate firmwarecommit. Enter all
requested information (use default values). The following example shows the
results of running firmwaredownload for Fabric OS version 7.0.0a.
SAN768B-2_124:admin> firmwaredownload -sU v7.0.0a
Server IP: 10.31.2.25, Protocol IPv4
Checking system settings for firmwaredownload...
System settings check passed.
You are running firmwaredownload with auto-reboot disabled.
After firmware is downloaded, please reboot the system to
activate the new firmware.
Firmware is being downloaded to the switch. This step may take up to 30
minutes.
Preparing for firmwaredownload...
2011/05/24-10:59:39, [SULB-1001], 7258, SLOT 7 | CHASSIS, WARNING,
SAN768B-2, Firmwaredownload command has started.
2011/05/24-10:59:39, [SULB-1036], 7259, SLOT 7 | CHASSIS, INFO,
SAN768B-2,
The current Version: Fabric OS v7.0.0
Start to install packages...
dir ##################################################
ldconfig ##################################################
<some output removed>