Introduction - Patton electronics 4630 Series Getting Started Manual

Isdn bri s0 voip gateway router
Table of Contents

Advertisement

SmartNode 4630 Getting Started Guide

Introduction

The factory configuration settings for SmartNode 4630 are as follows:
#----------------------------------------------------------------#
#
# 4110/4520/4630 Series
# R3.xx BUILDxxxxx
# 2005-01-18T00:00:00
# Factory configuration file
#
#----------------------------------------------------------------#
profile napt NAPT
profile dhcp-server DHCP
network 192.168.1.0 255.255.255.0
include 192.168.1.10 192.168.1.19
lease 2 hours
default-router 192.168.1.1
context ip router
interface eth0
ipaddress 172.16.40.1 255.255.0.0
use profile napt NAPT
interface eth1
ipaddress 192.168.1.1 255.255.255.0
context ip router
dhcp-server use DHCP
port ethernet 0 0
encapsulation ip
bind interface eth0 router
no shutdown
port ethernet 0 1
encapsulation ip
bind interface eth1 router
no shutdown