To perform a V.52 test, follow these steps:
1.
Activate the local loopback or remote loopback diagnostic.
2.
Activate the test pattern. This may be done in one of two
ways:
a.
Enter
Diagnostics/Statistics menu and toggle the <Spacebar>
until the desired test pattern appears.
b.
Enter
the selected pattern.
c.
One of two result codes will appear to the right of the
Test Pattern listing:
OK Indicates that the received test pattern is error-free.
BE Indicates that there are errors in the test pattern (to
deliberately insert errors in the pattern, toggle
Error Insertion to ON).
e
Selected Pattern from the System
c
Test Pattern and toggle the [Spacebar] to send
38