3.2 SOFTWARE CONFIGURATION
The Model 2720 features a menu-driven command system that
allows you to monitor/configure its operating parameters. Follow the
instructions below to configure the Model 2720 using the software
selections:
Position
S1-1
S1-2
S1-3
S1-4
S1-5
S1-6
S1-7
S1-8
1)
Plug the 9-pin male end of the cable to your terminal or com-
puter's DB-9 serial port and start up the terminal emulator
software if necessary. Plug the miniature stereo plug into the
rear of the unit. The small recessed jack on the left side of
the unit is the control port jack.
NOTE: If your terminal uses a DB-25 connector, please use a
DB-9 to DB-25 Adapter to connect to the cable.
2)
Power up the terminal and set its RS-232 port as follows:
S1 SUMMARY TABE
Function
RDL Type
Reserved
Tx Clock Invert
Line Build Out
Reserved
Reserved
Reserved
9600 Baud
8 data bits, 1 stop bit, no parity
Local echo off
ANSI or VT-100 emulation
Factory Default
On
On
Off
Off
Off
Off
Off
Off
12
Selected Option
V.54 RDL
Normal
0dB