Removing The High Limit - Whirlpool WED99HEDW0 Technical Education

Hybridcare duet dryer with heat pump technology
Table of Contents

Advertisement

Removing the High Limit and Auxiliary Fan
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
To Remove the High Limit Thermostat
1. Unplug dryer or disconnect power.
2. Remove drain hose from standpipe or laundry tub.
3. Perform the procedures on page 4-15, "Removing the
Rear Panel" prior to performing the following steps.
Heater
4. Disconnect the two terminal wires from the high limit
thermistor (see Figure 2).
5. Remove the two (2) 1/4" hex-head screws securing the
thermistor to the inlet duct (see Figure 2).
Remove
2 screws
High-Limit
Thermostat
Aux. Fan
Drain Port
Figure 1
Disconnect
thermistor
terminals
Figure 2
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
To Remove the Auxiliary Fan
1. Unplug dryer or disconnect power.
2. Remove drain hose from standpipe or laundry tub.
3. Perform the procedures on page 4-15, "Removing the
Rear Panel" prior to performing the following steps.
Heater
4. Disconnect the fan connector (yellow wires) as illustrated
in Figure 4.
5. Remove the two (2) 1/4" hex-head screws securing the fan
to the fan bracket (see Figure 4). Remove the fan assembly.
Disconnect
Fan Connector
HybridCare™ Dryer with Heat Pump Technology
COMPONENT ACCESS
High-Limit
Thermostat
Aux. Fan
Drain Port
Figure 3
Remove
2 screws
Figure 2
4-17
n

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wed99hedc0

Table of Contents