Test #5A: Adjusting Customer-Focused Dryness Level - Whirlpool WED99HEDW0 Technical Education

Hybridcare duet dryer with heat pump technology
Table of Contents

Advertisement

TESTING
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
FOR SERVICE TECHNICIAN'S USE ONLY
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
CYCLE CONTROL UNIT
P9-2
K1
MOTOR RELAY
CYCLE CONTROL UNIT
BK
N.O.
RELAY K3
THERMISTORS STRIP CIRCUIT (refer to page 6-14 for diagnostics)
CYCLE CONTROL UNIT
COMPRESSOR
P14-1
THERMISTOR
OUTLET
P14-3
THERMISTOR
n
6-16
HybridCare™ Dryer with Heat Pump Technology
CYCLE CONTROL UNIT
For Service Technician Use Only
LBU
LBU
P9-1
CENTRIFUGAL SWITCH
See
R
COM1
Motor
Circuit
3M
COMPRESSOR TEMP THERMISTOR
PK
R-W
OUTLET TEMP THERMISTOR
TEST #5a: Adjusting Customer-Focused
Dryness Level
NOTE: If the customer complains about the clothes being less
dry or more dry than desired and the moisture sensor passes
TEST #5: Moisture Sensor, step 2, the total dry time can be
lengthened or shortened by changing the Customer-Focused
Dryness Level from "1" (standard auto cycle) to a "2" (15%
more drying time), "3" (30% more drying time), "4" (15% less
drying time), or "5" (30% less drying time) auto cycle.
1. In standby mode (dryer plugged in but not powered up),
press and hold the DRYNESS LEVEL button for approximately
3 seconds. The dryer will beep and "CF" is displayed followed
by the current dryness setting on the 7-segment display. The
factory default value is "1".
2. Pressing the dryness level button cycles the dryness setting
between 1, 2, 3, 4, and 5 in that order, starting at the current
setting. The new setting is displayed in the 7-segment display.
3. With the display showing the desired dryness setting, press
the START button to save the drying mode and exit to standby
mode (the START button in this mode does not start a drying
DRIVE MOTOR
cycle). The result will be stored in EEPROM of the CCU and will
1/3 HP
be retained after a power loss.
MAIN
NOTE: If there is no user activity for 20 seconds, or a button
other than START or DRYNESS LEVEL is pressed, the dryness
4M
setting is reverted back to its previous setting.
BU
4. Press the POWER button at any time to cancel changes and
THERMAL
PROTECT
exit from this mode.
START
2M
V
5M
1M
6M
R
10K
10K
CENTRIFUGAL
SWITCH
W
5M
2M
1M
3M
6M
See Heater Circuit
V
HEATER
V
CYCLE CONTROL UNIT
V
COMPRESSOR
P14-2
THERMISTOR RTN
Y
P14-6
THERMISTOR RTN
CYCLE CONTROL UNIT
N
W
LBU
N.O.
BU
W
DOOR
SWITCH
L2
HIGH LIMIT
THERMOSTAT
R
OUTLET