Troubleshooting
Fault description
Pump runs permanently,
water in the grounds con-
tainer.
Choco/topping container
cannot be inserted.
BA SCV_EN
V05 | 04.2013
Cause and effect
PC board defective.
Electrical problem between the pump and the
PCB.
Position of the dosing screw is wrong
What to do
► Switch the machine off and back on.
► Disconnect the machine from the mains pow-
er supply and reconnect it.
► If not rectified, contact your service partner.
► Manually turn the dosing screw drive slightly
clockwise.