YASKAWA A1000 Quick Start Manual page 30

Frequency high performance vector control ac drive
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

6 Parameter Table
Monitor
U2-05
Output Current at Previous Fault
U2-06
Motor Speed at Previous Fault
U2-07
Output Voltage at Previous Fault
U2-08
DC Bus Voltage at Previous Fault
U2-09
Output Power at Previous Fault
U2-10
Torque Reference at Previous Fault
U2-11
Input Terminal Status at Previous Fault
U2-12
Output Terminal Status at Previous Fault
U2-13
Drive Operation Status at Previous Fault
U2-14
Cumulative Operation Time at Previous Fault
U2-15
Soft Starter Speed Reference at Previous Fault
U2-16
Motor q-Axis Current at Previous Fault
U2-17
Motor d-Axis Current at Previous Fault
U2-20
Heatsink Temperature at Previous Fault
Fault History
U3-01 to
First to 4th Most Recent Fault
U3-04
U3-05 to
5th to 10th Most Recent Fault
U3-10
U3-11 to
Cumulative Operation Time at 1st to 4th Most Recent
U3-14
Fault
U3-15 to
Cumulative Operation Time at 5th to 10th Most Recent
U3-20
Fault
NOTE: The following faults are not recorded in the error log.
CPF00 to 03, Uv1, and Uv2
DI/DO Sel.
Digital Input Function Selections
3
Multi-step speed reference 1
4
Multi-step speed reference 2
5
Multi-step speed reference 3
Jog reference selection (higher priority than multi-step
6
speed reference)
7
Accel/decel time selection 1
F
Through mode (Set when a terminal is not used)
14
Fault reset (Reset when turned ON)
External fault; Input mode: N.O. contact / N.C. contact,
20 to 2F
Detection mode: Normal/during operation
Digital Output Function Selections
During Run (ON: run command is ON or voltage is being
0
output)
1
Zero Speed
2
Speed Agree 1
6
Drive Ready
E
Fault
F
Through mode
10
Minor fault (Alarm) (ON: Alarm displayed)
30
Description
Description
YASKAWA ELECTRIC TOEP C710616 27D YASKAWA AC Drive - A1000 Quick Start Guide

Advertisement

Table of Contents
loading

Table of Contents