3 Electrical Installation
Type
No.
M1
Multi-function digital output (During run)
M2
Multi-Function
M3
Multi-function digital output (Zero speed)
Digital Output
M4
M5
Multi-function digital output (Speed agree 1)
M6
Pulse train output (Output frequency)
MP
Analog monitor output 1 (Output frequency)
FM
Monitor Output
Analog monitor output 2 (Output current)
AM
Monitor common
AC
DM+ Safety monitor output
Safety Monitor
Output
Safety monitor output common
DM-
NOTICE: The terminals HC, H1, H2 are used for the Safe Disable function. Do not remove the wire link between HC, H1, or H2 unless
the Safe Disable function is used.
NOTICE: The wiring length to the terminals HC, H1 and H2 should not exceed 30 m.
18
Terminal Name (Function)
Refer to Safe Disable Input Function on page 35
YASKAWA ELECTRIC TOEP C710616 27D YASKAWA AC Drive - A1000 Quick Start Guide
Function (Signal Level) Default Setting
30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A
Minimum load: 5 Vdc, 10 mA
30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A
Minimum load: 5 Vdc, 10 mA
30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A
Minimum load: 5 Vdc, 10 mA
32 kHz (max)
-10 to +10 Vdc, 0 to +10 Vdc, or 4 to 20 mA
Use jumper S5 on the control terminal board to select between voltage
or current output at terminals AM and FM. Set parameters H4-07 and
H4-08 accordingly when changing the jumper setting.
0 V
Outputs status of Safe Disable function. Closed when both Safe
Disable channels are closed. Up to +48 Vdc 50 mA
when using this function.