Advertisement

Maintenance (continued)
Recommended preventive maintenance
1) Dispense Valves
Check all dispense valves for lime build-up.
Drain the water tank to just below the level of
the dispense valves.
Remove the valves and clean. (Take these valves
apart by hand as shown).
Replace the assembly as needed (L467AL -120V
or L676AL - 230V import).
Replace the valve into the tank and refill tank.
Repair Kit M491QL.
WATER FLOW ADJUSTMENT
Dispense Valve
GB Series
2) •
Check all chamber mounts for signs of wear:
Product running down the front of the unit.
Product built up on the back of chamber
mount.
Remove chamber mount.
Clean and re-lubricate motor shaft using food
grade lubricant only.
Replace with new chamber mount. 
3) •
Clean out vent motor, trough, and tubing.
Lift up black tabs, remove trough drawer.
Clean and replace trough drawer.
Remove hose assembly from the motor.
Clean out and replace hose. 
Chamber Mount
Cecilware
®
11