Maintenance (continued)
Recommended preventive maintenance
1) Dispense Valves
•
Check all dispense valves for lime build-up.
•
Drain the water tank to just below the level of
the dispense valves.
•
Remove the valves and clean. (Take these valves
apart by hand as shown).
•
Replace the assembly as needed (L467AL -120V
or L676AL - 230V import).
•
Replace the valve into the tank and refill tank.
•
Repair Kit M491QL.
WATER FLOW ADJUSTMENT
Dispense Valve
GB Series
2) •
Check all chamber mounts for signs of wear:
•
Product running down the front of the unit.
•
Product built up on the back of chamber
mount.
•
Remove chamber mount.
•
Clean and re-lubricate motor shaft using food
grade lubricant only.
•
Replace with new chamber mount.
3) •
Clean out vent motor, trough, and tubing.
•
Lift up black tabs, remove trough drawer.
•
Clean and replace trough drawer.
•
Remove hose assembly from the motor.
•
Clean out and replace hose.