Cabling specifications

Twisted-pair
copper
Multimode fiber
Single mode
fiber
*A mode conditioning patch cable may be needed for some Gigabit-LX installations. See
cable (fiber cables)" (page 24)
NOTE:
Note on 1000BASE-T Cable Requirements:
The Category 5 networking cables that work for 100BASE-TX connections should also work for
1000BASE-T, as long as all four-pairs are connected. But, for the most robust connections, you
should use cabling that complies with the Category 5e specifications, as described in Addendum
5 to the TIA-568-A standard (ANSI/TIA/EIA-568-A-5). Because of the increased speed provided
by 1000BASE-T (Gigabit-T), network cable quality is more important than for either 10BASE-T or
100BASE-TX. Cabling plants being used to carry 1000BASE-T networking must comply with the
IEEE 802.3ab standards. In particular, the cabling must pass tests for Attenuation, Near-End
Crosstalk (NEXT), and Far-End Crosstalk (FEXT). Additionally, unlike the cables for 100BASE-TX,
the 1000BASE-T cables must pass tests for Equal-Level Far-End Crosstalk (ELFEXT) and Return Loss.
When testing your cabling, be sure to include the patch cables that connect the controller and
other end devices to the patch panels on your site. The patch cables are frequently overlooked
when testing cable and they must also comply with the cabling standards.

Cabling distance specifications

Technology
100-FX
100-BX
1000-T
1000-SX
100–LX
1000-LH
22
Specifications
10 Mbps
Category 3, 4 or 5, 100-ohm unshielded twisted-pair (UTP) or shielded twisted-pair
Operation
(STP) cable, complying with IEEE 802.3 10BASE-T specifications.
100 Mbps
Category 5, 100-ohm UTP or STP cable, complying with IEEE 802.3u 100BASE-TX
Operation
specifications.
1000 Mbps
Category 5, 100-ohm 4-pair UTP or STP cable, complying with IEEE 802.3ab
Operation
1000BASE-T specifications—Category 5e or better is recommended. See Note
on 1000BASE-T Cable Requirements below.
2.5/125 mm or 50/125 mm (core/cladding) diameter, low metal content, graded
index fiber-optic cables, complying with the ITU-T G.651 and ISO/IEC 793-2
Type A1b or A1a standards respectively.*
9/125 um (core/cladding) diameter, low metal content fiber-optic cables,
complying with the ITU-T G.652 and ISO/IEC 793-2 Type B1 standards.
for more information.
Supported cable type
multimode fiber
single mode fiber
twisted-pair copper
multimode fiber
multimode fiber
single mode fiber
single mode fiber
Multimode fiber modal
bandwidth
any
N/A
N/A
160 MHz*km
200 MHz*km
400 MHz*km
500 MHz*km
400 MHz*km
500 MHz*km
N/A
N/A
"Mode conditioning patch
Supported distances
up to 2,000 meters
0.5 - 10,000 meters
up to 100 meters
2 - 220 meters
2 - 275 meters
2 - 500 meters
2 - 550 meters
2 - 550 meters
2 - 550 meters
2 - 10,000 meters
10 - 70,000 meters*