Troubleshooting; Table Of Events - Eltek Valere THEIA S User Manual

String inverters solar grid-tie inverters 2.1kw to 4.6kw
Table of Contents

Advertisement

11.

Troubleshooting

Table of events

To isolate the error, have the following information ready when calling the service:
— displayed error number (No)
— serial number of the inverter (see Chapter 6, section Information)
No
Operating status
Blocking errors
90
AC voltage too high
91
DC voltage too high
92
Polarity of DC connection
reversed
93
Insulation error between
PV+ or PV- and earth
Blocking errors
100
Blocking system error
to
103
104
DC voltage too high
105
Startup: Polarity of DC
connection reversed
106
Blocking system error
to
129
Connections L and N
130
reversed
131
System error
to
199
Non-blocking errors
201
Amplitude limit for feed
phase exceeded or fallen
below
202
Exclusively for 3 phase
to
ENS. Amplitude limit of
204
phase voltages exceeded
54
Measure
Separate inverter from mains. Check connection of AC plug.
Separate inverter from mains. Separate inverter from DC terminal.
Check module interconnection.
Check DC connection.
Check insulation of PV modules. Check insulation of PV wiring.
Separate inverter from mains. Restart inverter. If measure is not
successful call service personnel.
Check module interconnection.
Check DC connection.
Separate inverter from mains. Restart inverter. If measure is not
successful call service personnel.
Check L and N connections on AC plug
Separate inverter from mains. Restart inverter. If measure is not
successful call service personnel.
Have voltage amplitude of feed phase checked.
Ensure that all fuses are switched on. Startup:- have inverter 3-
phases connected.
User's Guide THEIA S String Inverters
357100.013, Issue 2.0, 2010 Aug