To disconnect the inverter:
• Switch off the main power supply (fuse)
• Unlock and pull the feed output plug (AC-side)
• Pull plug connector of output voltage (DC side) or set DC disconnector to '0'
• Disconnect remaining connectors as required
Dismount the inverter as follows:
• Loosen and remove the locking screws (paper strip)
• Lift the inverter up and out of the mounting fixture
Remove the mounting fixture as follows:
• Unscrew the mounting fixture
• Insert the mounting fixture at the back of the inverter
• Secure the mounting fixture with the locking screws

Return Consignment

In case of a return consignment:
• Pack the inverter in the packaging of the replacement.
If a single inverter is returned:
• Re-use the original packaging, or pack securely with alternative packaging.
User's Guide THEIA S String Inverters
357100.013, Issue 2.0, 2010 Aug
51